www.BISSELLdirect.co.uk
11
Troubleshooting
Problem
Possible causes
Remedies
Reduced
spray OR
no spray
Bladder may be empty.
Turn power switch OFF; Refill bladder with clean
hot tap water and cleaning formula.
2-in-1 Water Tank may not
be seated properly.
Turn power switch OFF; remove tank and reseat
tanks.
Pump may have lost prime.
Turn power switch OFF; after 1 minute turn ON
and press spray trigger.
The pump belt may be
broken.
Turn power switch OFF and unplug from the
outlet. To check if a pump belt has broken, you
will need a flathead screwdriver.
A.
Insert the
blade end into the slot of the Belt Access Door
to release. Examine the belt for breakage. You
should be able to see the pump belt looped
around the motor shaft. If it is broken or missing.
A replacement belt may be ordered by calling
BISSELL® Consumer Care. Complete installation
instructions will accompany the replacement belt.
B.
When replacing Belt Access Door be sure to
line up slots of door with slots in machine, slide
door into place and snap shut.
DirtLifter
PowerBrush
does not turn
The brush belt or pump
belt is off or broken.
Refer to remedy in “The pump belt may be
broken” above to check if brush belt or pump
belt is broken.
Machine
not picking
up solution
ReadyTools Dial may be on
the wrong setting.
Set dial to either FLOOR CLEANING or TOOLS for the
cleaning job.
Poor tool position.
(Handheld attachments
only.)
Adjust angle; apply more downward pressure.
Removable Nozzle may not
be properly attached.
Make sure nozzle is on correctly by slightly raising
front of machine to line up slots on the base of
the machine with the hooks on nozzle. Attach at
base first and then click nozzle into place.
2-in-1 Water Tank lid is not
properly installed.
Re-install lid.
2-in-1 Water Tank is not
properly seated.
Remove and reseat tank.
2-in-1 Water Tank has
picked up maximum dirty
water.
Empty tank.
The lint screen may be
clogged.
Clean out lint screen.
WARNING
To reduce the risk of electric shock, turn power
OFF
and disconnect plug from electrical outlet before
performing maintenance or troubleshooting checks.