w w w . b i s s e l l . c o m 8 0 0 . 2 3 7 . 7 6 9 1
M
aintenance and care
14
Replace drive belt
1.
Unplug the vacuum from electrical outlet.
2.
With rotating floor brush removed from
vacuum cleaner (steps 1 – 4 of check rotat-
ing floor brush and drive belt page13),
grasp old drive belt and remove from
motor pulley. Discard the old drive belt.
3.
Place one end of the new drive belt over
motor pulley and the other end over the
brush in the space between the bristles.
note: it is important that you
use only genuine bissell
replacement parts. generic
belts may not meet the exact
specifications required to keep
your vacuum operating at its
peak performance. the use of
unbranded belts could lead to
early failure of the vacuum and
could void your warranty.
4.
Pull the brush firmly to stretch the drive
belt and place ends of brush down into
slots on sides. Turn brush several times by
hand to center the drive belt.
5.
Reposition brush cover and screws.
Tighten screws securely.
brush reset
if something becomes lodged in
the foot and the brush shuts off,
turn the cleaner off and unplug
from the outlet. Remove the
obstruction. the brush will
automatically reset when the
cleaner is plugged in and turned
back on.
2
3