Supplier Name or Trade Mark
Model Identifier
Options Installed
1
SEC in [kWh/(m²a)] for Each Climate
2
(Cold, Average, Warm)
-50.2
-25.1
-10.7
SEC Class
(Cold, Average, Warm)
A+
C
E
Declared Typology
Type of Motor Drive Installed
Type of Heat Recovery
3
Heat Recovery Efficiency
4
Maximum Flow Rate in [m³/h] / [l/s]
5
Electric Power Input at Maximum Flow Rate [W]
6
Sound Power Level (L
WA
) in [dB(A)] Maximum / Trickle
7
Sound Pressure Level (L
PA
) in [dB(A)] Maximum / Trickle
8
Reference Flow Rate in [m³/h] / [l/s]
9
Reference Pressure Difference
SPI in [W/(m³/h)]
10
Control Factor and Typology
Declared Maximum Internal and External Leakage [%]
11
Position and Description of Visual Filter Warning
Internet Address for Preassembly / Disassembly Instructions
1: Type of Sensor: Integral Humidity Sensor or via Occupancy Sensor, i.e. switch-live activation.
2: Continuous Ventilation: SEC calculations based on unit running on trickle speed continuously & boost 1
1
/
2
hours per day.
3: Type of Heat Recovery: Recuperative is without humidity recovery and Renewable is with humidity recovery.
4: Efficiency according to EN13141-7:2010 at reference airflow rate @ 0 Pa; and according to EN13141-8:2014 systems without connection.
5: Maximum flow at 0 Pa external pressure (shown in both m
3
/h and l/s).
6. Electrical power input at the maximum airflow rate (Watts).
7: Casing noise radiation at both maximum and trickle flow rates at 0 Pa external pressure.
8: Sound Pressure Level measured at 3 metres.
9: If applicable, reference flow rate is 70% of the maximum airflow at 0 Pa external pressure according to EN13141-7:2010 (shown in both m3/h and l/s).
10: In accordance with EN13141-7:2010 at reference flow rate.
11: In accordance with EN13141-7:2010 at reference flow rate, and EN13141-8:2014 systems without connection.
SEC: Specific Energy Consumption
SPI:
Specific Power Input
AEC: Annual Electricity Consumption
AHS: Annual Heating Saved
0.65
n/a
0
www.bisque.co.uk
Declaration of Performance
Residential Ventilation Unit Bisque Serenity Fans
Bisque
Local Demand Control
(with 1 sensor)
SEFBR / MR
Multi-Speed
None
Unidirectional
5.5
31 / 27
n/a
54 / 15
14 / 10
Internal: n/a
External: n/a
n/a
0.10