background image

Supplier Name or Trade Mark

Model Identifier

Options Installed

1

SEC in [kWh/(m²a)] for Each Climate

2

(Cold, Average, Warm)

-50.2

-25.1

-10.7

SEC Class
(Cold, Average, Warm)

A+

C

E

Declared Typology

Type of Motor Drive Installed

Type of Heat Recovery

3

Heat Recovery Efficiency

4

Maximum Flow Rate in [m³/h] / [l/s]

5

Electric Power Input at Maximum Flow Rate [W]

6

Sound Power Level (L

WA

) in [dB(A)] Maximum / Trickle

7

Sound Pressure Level (L

PA

) in [dB(A)] Maximum / Trickle

8

Reference Flow Rate in [m³/h] / [l/s]

9

Reference Pressure Difference

SPI in [W/(m³/h)]

10

Control Factor and Typology

Declared Maximum Internal and External Leakage [%]

11

Position and Description of Visual Filter Warning

Internet Address for Preassembly / Disassembly Instructions

1: Type of Sensor: Integral Humidity Sensor or via Occupancy Sensor, i.e. switch-live activation.

2: Continuous Ventilation: SEC calculations based on unit running on trickle speed continuously & boost 1 

1

/

2

 hours per day.

3: Type of Heat Recovery: Recuperative is without humidity recovery and Renewable is with humidity recovery.

4: Efficiency according to EN13141-7:2010 at reference airflow rate @ 0 Pa; and according to EN13141-8:2014 systems without connection.

5: Maximum flow at 0 Pa external pressure (shown in both m

3

/h and l/s).

6. Electrical power input at the maximum airflow rate (Watts).

7: Casing noise radiation at both maximum and trickle flow rates at 0 Pa external pressure. 

8: Sound Pressure Level measured at 3 metres.

9: If applicable, reference flow rate is 70% of the maximum airflow at 0 Pa external pressure according to EN13141-7:2010 (shown in both m3/h and l/s).

10: In accordance with EN13141-7:2010 at reference flow rate.

11: In accordance with EN13141-7:2010 at reference flow rate, and EN13141-8:2014 systems without connection.

SEC: Specific Energy Consumption

SPI: 

  

Specific Power Input

AEC: Annual Electricity Consumption

AHS: Annual Heating Saved

0.65

n/a

0

www.bisque.co.uk

Declaration of Performance 

Residential Ventilation Unit Bisque Serenity Fans

Bisque

 Local Demand Control

(with 1 sensor)

SEFBR / MR

Multi-Speed

None

Unidirectional

5.5

31 / 27

n/a

54 / 15

14 / 10

Internal: n/a

External: n/a

n/a

0.10