DIVE MODE (DIVE)
40
●Gas can be changed by this operation, but if the depth is deeper than the maximum operating
depth, the gas change is not possible and the display will not change even if the button is
depressed.
●When the diving depth becomes deeper than the maximum operating depth of the currently
selected gas while the gas change screen is displayed, the buzzer sounds once and the gas
changes to the gas that can be changed. (Unconfirmed state) It is possible to change the gas by
ascending to the maximum operating depth and performing the gas change operation again.
●After a few minutes on the gas change screen, the gas currently selected is confirmed and the
screen returns to the basic screen.
●The maximum operating depth is set at partial pressure of oxygen 1.6 bar. However, on the
gas change screen, the Nx mark blinks when the partial pressure of oxygen exceeds 1.4 bar.
●The Nx mark will blink for up to 24 hours on the surface screen after diving with multiple
gas setting or with Nitrox setting. If you enter the gas setting screen and check the fraction of
oxygen while the Nx mark is blinking, the Nx mark blinking will disappear.
If you dive while the Nx mark is blinking, the buzzer will sound for 6 seconds, and for safety it
will be calculated with 50% oxygen and 79% nitrogen, so be sure to check the gas settings in
the “Plan Mode”.