background image

Page 10 of 12 

 6001099 Birko Tempo Tronic 03.2017 v1.00

Spare Parts List

Item

Kit No

Description

1

1311055

Birko Tap assy TT

2

1311059

Tap Insert Assy Birko

3

1312222

Escutcheon Black TT

4

1312223

Tap Lock Nut (w/ Flats)

5

1312224

Timer Loom Birko TT 5l

6a

1312225

Thermostat EA3513R 88º+/-1.5

6b

1312226

Thermostat EA3513A 85º+/-1.5

7a

1312227

Inlet assy 3l

7b

1312228

Inlet assy 5l

7c

1312229

Inlet assy 7.5l

7d

1312230

Inlet assy 15l

7e

1312231

Inlet assy 25l

8

1312232

Filter cold inlet bush (plastic)

9a

1312233

Bush vent assy 3l

9b

1312234

Bush vent assy 5l

9c

1312235

Bush vent assy 7.5l

9d

1312236

Bush vent assy 15l

9e

1312237

Bush vent assy 25l

10

1312238

Loom Birko TT Ther-Overload

11

1315320

Timer 7day-24Hr Gray

12

1312239

Lid, Cistern TT

13

1312240

Jumper Valve Assy

14

1311013

Floating Ball ASSY

15

1311031

Overload 4 terminal, 2 pole, 90 deg

16

1312242

Tank, Cistern

17

1312243

Seal Transfer Tube 2000B

18

1312244

Metering Tube 2.4kW 

19

1312245

Elbow Stem 1/4" x 1/4" JG

20a

1312246

Tank Assy S/S TT 3 Ltr

20b

1312247

Tank Assy S/S TT 5 Ltr

20c

1312248

Tank Assy S/S TT 7.5 Ltr

20d

1312249

Tank Assy S/S TT 15 Ltr

20e

1312250

Tank Assy S/S TT 25 Ltr

21

1312251

O Ring BS114 Silicone

22a

1312252

Element 2400/240v HS2005B

22b

1312253

Element, 1500 (3l)

Содержание Tempo Tronic 15L S/S

Страница 1: ...1 of 12 1090074 Tempo Tronic 3L S S 1090076 Tempo Tronic 5L S S 1090078 Tempo Tronic 7 5L S S 1090082 Tempo Tronic 15L S S 1090086 Tempo Tronic 25L S S 1100076 Tempo Tronic 5L S S Timer Birko Tempo T...

Страница 2: ...ing 5 b Venting 5 c Electrical 6 Step 4 Assembling 6 Step 5 Commissioning 6 Operating Procedures 7 Earthing Continuity Verification 7 Problem Solving 8 Wall Mounting Template Dimensions 9 Cleaning 9 E...

Страница 3: ...circumstances without first isolating the heater from the power supply Do not use strong corrosive or abrasive cleaners to clean the case of the heater Frost protection If this heater is located wher...

Страница 4: ...drip tray Position the base of the tap to be not less than 200 mm above the draining board height should be increased only if essential for filling larger vessels Provide clearance for service access...

Страница 5: ...Pa maximum 500 kPa Warning If pressure is likely to exceed 500 kPa a pressure limiting valve must be installed in the cold water supply line Birko recommends a valve rated at 350 kPa for this applicat...

Страница 6: ...the way to escutcheon tube then apply PTFE tape to the threaded portion of the outlet tube if not already applied See Fig 1 Screw the tap assembly clockwise onto the outlet tube until it touches the...

Страница 7: ...illed without holding your hand where it may be affected by steam Earthing Continuity Verification Warning this appliance must be earthed Following remedial service the earthing continuity of the heat...

Страница 8: ...ve Contact Birko authorised agent Water not boiling No power Faulty thermostat faulty element faulty cutout Incorrect timer setting Check power supply Contact Birko authorised agent Check timer settin...

Страница 9: ...ld soap and water Wall Mounting Template Dimensions 3 0 L 3 0 L End of Life Disposal In order to help preserve our environment we ask that you dispose of this product correctly Please contact your loc...

Страница 10: ...l 9b 1312234 Bush vent assy 5l 9c 1312235 Bush vent assy 7 5l 9d 1312236 Bush vent assy 15l 9e 1312237 Bush vent assy 25l 10 1312238 Loom Birko TT Ther Overload 11 1315320 Timer 7day 24Hr Gray 12 1312...

Страница 11: ...6001099 Birko Tempo Tronic 03 2017 v1 00 Page 11 of 12 Exploded View Diagram 11 3 4 1 20 6 21 22a 5 10 17 9 18 17 17 14 13 12 19 15 8 7 16 2 22b...

Страница 12: ...of continuous product improvement changes to specifications may be made without prior notice Images in this booklet have been modified and may not be true representations of the finished goods The st...

Отзывы: