background image

Chapter 1

Introduction

Purpose and

Function

The Bird Model 8135 TERMALINE Load Resistor is a por-

table, general purpose 50 ohm coaxial transmission line ter-

mination. It is a self-contained unit requiring no outside

power source or additional equipment. This coaxial load re-

sistor provides an accurate, dependable, and practically

non-reflective termination for adjustment, standby, and

testing of transmitters under nonradiating conditions.

Performance

Characteristic

s and

Capabilities

The Model 8135 can absorb up to 150 watts continuously

and dissipate it harmlessly as heat over a frequency range

of dc to 4000 MHz. It is designed to show low reflectivity

throughout this range. The VSWR will be 1.1 to 1.0 maxi-

mum from dc to 1000 MHz, 1.2 to 1.0 maximum from 1000

to 2500 MHz and 1.3 to 1.0 maximum from 2000 to 4000

MHz.

Dimensions

and Weight

The Model 8135 is 8-13/16 inches long, 4 inches wide, and

6-7/16 inches high (224 x 102 x 164 mm). It has a weight of

6 lb (2.7 kg) net and a shipping weight of 8 lb (3.6 kg).

Power and

Utility

Requirements

Being a passive electronic device, the Model 8135 needs no

outside source or utility service.

Enviromental

Requirements

The Model 8135 should be used in a dust and vibration-free

environment. The ambient temperature range should be

kept between -40C and +45C (-40F and +113F) for proper

operation. Allow at least 6 inches of clearance around the

load to permit an unimpeded access of convection air cur-

rents to the load.

Items

Furnished

The RF input connector, located on the front face of the unit,

is a Female N. It is a special “Quick-Change” design permit-

ting rapid and easy interchange with other Bird AN type

“QC” connectors. This instruction book is the only other

item provided.

Items

Required

The only other item required is a matching connector on the

coaxial transmission line.

Tools and

Test

Equipment

Only simple tools like screwdrivers are needed to disassem-

ble the Model 8135. A resistance bridge or ohmmeter with

an accuracy of one percent or better at 50 ohms is useful for

checking the resistance value of the RF section assembly.

1

Содержание TERMALINE 8135

Страница 1: ...ALINE COAXIAL LOAD RESISTOR MODEL 8135 Electronic Corporation Cleveland Solon Ohio USA Copyright 1996 by Bird Electronic Corporation Instruction Book Part Number 920 8135 Rev B Termaline is a Register...

Страница 2: ......

Страница 3: ...le power is applied When working with high voltage al ways have someone present who is capable of rendering aid if necessary Per sonnel working with or near high voltage should be familiar with modern...

Страница 4: ...appear in the test where there is danger to op erating and maintenance personnel and are repeated here for emphasis WARNING When power is in the upper range of the load s capacity the radiator will be...

Страница 5: ...perienced operator can refer to Chapter 4 Operating Instructions All instructions necessary to operate the equipment are contained in this sec tion MAINTENANCE All personnel should be familiar with pr...

Страница 6: ...racteristics and Capabilities 1 Dimensions and Weight 1 Power and Utility Requirements 1 Environmental Requirements 1 Items Furnished 1 Items Required 1 Tools and Test Equipment 1 Theory of Operation...

Страница 7: ...iator 10 Inspection 10 Oil Leakage 10 Cleanliness 10 Completeness 10 Preventive Maintenance 10 RF Assembly Test 10 Disassembly 11 RF Input Connector Replacement 11 Diaphragm and Coolant Oil 11 RF Load...

Страница 8: ...Replacement Parts List 13 Difference Data Sheet 15 VSWR Difference 15 Operating position 15 Bird Model 8135 Termaline Coaxial Load Resistor vi...

Страница 9: ...It has a weight of 6 lb 2 7 kg net and a shipping weight of 8 lb 3 6 kg Power and Utility Requirements Being a passive electronic device the Model 8135 needs no outside source or utility service Envir...

Страница 10: ...inuous Frequency Range DC 4000 MHz Dimensions 8 13 16 L x 4 W x 6 7 16 H 224 x 102 x 164 mm Ambient Temperature 40C to 45C 40F to 113F Cooling Method Dielectric liquid air convection Weight Nominal 6...

Страница 11: ...es of the load Dielectric Coolant and Seal The coolant oil is chosen for its desirable dielectric proper ties and thermal characteristics Cooling of the load is ac complished by natural fluid and air...

Страница 12: ...Bird Model 8135 Termaline Coaxial Load Resistor 4...

Страница 13: ...l position to insure that the load resistor will always be immersed in the coolant Mounting The Model 8135 may be fastened to a work or test bench To do this remove the four rubber bumpers from the bo...

Страница 14: ...Bird Model 8135 Termaline Coaxial Load Resistor 6...

Страница 15: ...ssi ble differences in VSWR Normal Operation Being a passive device the Model 8135 will function without an operator in attendance provided its stated performance limits are not exceeded WARNING When...

Страница 16: ...the RF source as in the above procedure WARNING Never attempt to disconnect the equipment from the transmission line while RF power is being applied Leaking RF energy is a potential health hazard Bir...

Страница 17: ...mbly Faulty dia phragm rear Replace per para Disassembly Di aphragm and Coolant Oil Overheating of the radiator Transmitter power too high Reduce transmit ter power Coolant oil level too low Add more...

Страница 18: ...ng bands both front and back Cleanliness Check for cleanliness of the radiator fins and the RF connec tor Proceed as in paragraph Cleaning Completenes s Inspect the Model 8135 Termaline Load for compl...

Страница 19: ...place or examine the coolant oil Replacement of the diaphragm and coolant oil are out lined in the following steps 1 Stand the load vertically with the back end up 2 Loosen the clamp screw until clamp...

Страница 20: ...tor Assembly To replace the load assembly reverse the procedure in the RF Load Resistor Assembly paragraph Customer Service Any maintenance or service procedure beyond the scope of those provided in t...

Страница 21: ...ectric coolant before shipping Replacement Parts List Model 8135 Maintenance 13 Available QC Type Connectors N Female 4240 062 LT Female 4240 018 N Male 4240 063 LT Male 4240 012 HN Female 4240 268 C...

Страница 22: ...Bird Model 8135 Termaline Coaxial Load Resistor 14...

Страница 23: ...It will handle up to 35 kW peak power with a pulse width of one microsecond For further information on peak power rat ings contact the factory When ordering a new RF section for the Model 8135A order...

Страница 24: ...ade for amounts so expended by Buyer Every such claim for breach of these warranties shall be deemed to be waived by Buyer unless made in writ ing within ten 10 days from the date of discovery of the...

Страница 25: ...e above referenced product to which this declaration relates is in conformity with the provisions of the following standards 1 European Standard EN 61010 1 1993 Safety Group II This standard is in acc...

Отзывы: