Chapter 3
Installation
Location
Free air circulation around the Model 8135 TERMALINE
Load is essential. Keep the load in the clear, and do not
place it near heated surfaces. The Model 8135 should have
at least a 6 inch clearance on all sides. Keep the space above
the unit unobstructed for good air circulation. This load is to
be mounted only in a horizontal position to insure that the
load resistor will always be immersed in the coolant.
Mounting
The Model 8135 may be fastened to a work or test bench. To
do this, remove the four rubber bumpers from the bottom of
the radiator. These bumpers are fastened to the corners of
the bottom radiator brace by 8-32 studs which are set per-
manently into the rubber feet. The bumpers unscrew easily
by hand. The holes are threaded for 8-32 screws. The fasten-
ers must be placed up through the bench and into the load.
These holes are on a 3 x 7 inch rectangle (76 x 178 mm).
5