CAUTION
Do not 22 dBm (100
mW) RF Power input at the measurement port.
Damage to the units RF module will result.
Bird SiteHawk Operation Manual
23
Note:
Antenna systems can build up a static charge large enough to
damage the SiteHawk, if discharged through the device. It is
recommended a load or attenuator be used to bleed off any static
charge prior to connecting the SiteHawk to the system.
12. Connect the SiteHawk Analyzer to the cable being tested.
Note:
If the SiteHawk Analyzer is calibrated with a phase stable cable
connected to its antenna port, do not remove the cable. Connect it to
the cable to be tested.
13. Wait at least 10 seconds for the sweep to update.
14. Press the Menu icon, then Press MEM menu icon. Press CONTINUE and
verify Trigger toggles to HOLD.