8
Chapter 3
Specifications
5009 Specifications
Sensor
Type
Thruline
two
‐
element
line
section
Elements
DPM
elements
ONLY
Select
two
elements
from
the
same
series,
with
RFL
power
1/10
of
FWD
power.
Frequency
Range
1
2
–
1000
MHz
1
Average Power Measurements
DPM
Elements,
Forward
or
Reflected
Direction
Power
Measurement
Range
0.1
W
to
1
kW
Power
Measurement
Accuracy
±
5%
of
full
scale
average
power
(95%
c.l.)
Match Measurement
Match
Range
Return
Loss
Rho
(
)
VSWR
0
to
20
dB
0.1
to
1
1.22
to
99.99
Uncertainty
Twice
the
Avg
Power
Uncertainty
(Calculated
from
forward
and
reflected
uncertainty)
Settling
Time,
Max
2.5
seconds
Impedance,
Nominal
50
ohms
Insertion
Loss,
Max
0.05
dB
up
to
1
GHz
Input
VSWR,
Max.
1.05:1
up
to
1
GHz
Directivity,
Typical
1
30
dB
RF
Connectors
QC
Type
(N(F)
normally
supplied)
Interface
Connector
RJ
‐
25
Power
Supply
From
host
instrument
via
interface
cable
Mechanical
Shock
and
Vibration
In
accordance
with
MIL
‐
PRF
‐
28800F
Class
3
CE
CE
compliant.
Refer
to
DOC
for
specific
standards.
Recommended
Calibration
Interval
1
year
Temp,
Operating
–10
to
+50
°C
(+14
to
+122
°F)