Power Sensor Installation
8
4. Launch your web browser on a PC connected to the same network as the
4042E.
5. Enter the sensor’s newly assigned IP address in the web browsers address
box.
6. Connect sensor to RF delivery system. See
.
8. See
for descriptions of the sensor’s User
Interface.
RF Connections
1. Disable RF power for transmission lines to be disconnected.
2. Connect combiner's RF output cable to the 4042E RF input.
3. Connect 4042E's RF output connector to the antenna cable.
4. Repeat step
through
for any additional 4042E power sensors.
PTT Connections
PTT may be set to normally open or normally closed logic. The PTT terminals
must be in the correct logic state for PTT to operate correctly.
Note:
PTT input is a passive connection and requires a 5V TTL
signal to operate.
Figure 7 PTT Connections
The PTT settings in the User Interface must be enabled and set to correct logic to
match the PTT connection. See
.
WARNING
Leaking RF energy is a potential health hazard. Never attempt to connect or
disconnect equipment from the transmission line while RF power is being
applied. Severe burns, electrical shock, or death can occur.