manualshive.com logo in svg
background image

1

1

 2

ON

1

 2

ON

ON

1  2

ON

1  2

ON

1  2

RF

Gate 

3.2

 75 

44

 121 

 24 

 106 

 50 

 121 

 23 

 106 

 22

Wireless dual channel signal transmission system for safety edges 

Original operating instructions

General

1

Safety instructions

2

Common application

2.2   Industrial door

ENGLISH

370052A

05/18

Transmitter

Receiver

Warning:

 Switch off the operating voltage before working on the 

system. Only trained, qualified personnel may perform installation 
and startup. The unit may only be repaired by the manufacturer. The 
switching unit may only be used to protect against dangers on 
crushing and shearing points and on automatic industrial doors and 
gates (intended use). National and international regulations on 
industrial door and gate safety must be complied with. Always 

Transmitter 

Contact

Receiver 

Safety edge

Mobile  safety  edges      

Receiver

Transmitter 

Transmitter 1

Transmitter 2

DIP switch 2 OFF

Transmitter 2

Transmitter 1

Safety edge

8.2 kOhm

Contact 

(e.g.wicket door)

consider the safety functions of your application as a whole, never just in 
relation to one individual section of the system. The installer is responsible 
for carrying out a risk assessment and installing the industrial door system 
correctly.

i

Battery life up to 2 years, but it is recommended  
batteries are changed every 12 months.

Receiver

Receiver

Safety edge

8.2 kOhm

not used

not used

Safety edge

8.2 kOhm

DIP switch 2 ON

2.1   Sliding gate

Transmitter input 1 corresponds to receiver output 1

Transmitter input 2 corresponds to receiver output 2

i

Transmitter 1 (input 1) corresponds to receiver output 1

Transmitter 2 (input 1) corresponds to receiver output 2

i

Further transmitters with separate manuals

Batteries

CR2032

Push

button

Push

button

Отзывы: