background image

3

1

2

ON

1 2

+

+

2032

2032

ON

1 2

+

2032

1 2

ON

i

ON

OK?

1

 

2 3 4 

5

ON

2x

i

1 2 3 4 5

ON

1

 

2 3 4 

5

ON

2x

2x

6.2.  RFGate 2.2.NG, pairing transmitter with receiver

5

Start-up

6

Programming

2. 

On the  

transmitter

Press and 

release button

Beep

Wait

2

beeps

10 sec.

1. 

On the receiver

Press  

button

Beep

> 1.5 sec.

LED 

lights up

6.  

Transmitter: 

install

Release

button 

4.  

Transmitter: 

insert  

batteries

1.  

Check DIP 

switch settings

5.  

Programming (Chapter 6.1): 

pair transmitter with receiver

The distance between transmitter 
and receiver and further trans-
mitters must be at least 1 m

Observe

order

Code saved

LED goes out

Please observe the torque when 
fastening the cover:
Max. 45 N cm

7.  

Transmitter: 

wire

3.  

Turn on power 

supply

2.  

Install and wire 

receiver

8.  

System test of safety  

edge on gate

6.1  RFGate 2.2.A, pairing transmitter with receiver

2. 

On the trans-

mitter for  

channel 1

On the 

receiver

On the 

receiver

On the 

receiver

Press and 

release button

Beep

Wait

2

beeps

10 sec.

4. 

On the trans-

mitter for  

channel 2

Press and 

release button

Beep

Wait

10 sec.

3. 

On the receiver

Beep

Beep

Release

button

Release

button

LED 

lights up

LED  

flashes

Press  

button

> 1,5 sec.

Press  

button

> 1.5 sec.

1. 

On the receiver

Press  

button

Beep

> 1.5 sec.

LED 

lights up

Release

button

beeps

Code saved

LED goes out

Code saved

LED goes out

Beep

Beep

Beep

Beep

Beep

Beep

Beep

Beep

Beep

Beep

Status

Terminals  

COMx – OUTx

Terminals  

COMx – SOUTx

Sensor not activated (operating mode)

8K2

closed

Sensor activated (security system activated)

closed

open

No supply voltage

closed

open

Transmitter and receiver not paired

closed

open

Broken cable between sensor and transmitter

closed

open

Transmitter batteries low

closed

open

Отзывы: