5
Sensor Configuration
5.1
Configuration with keys
Le
ve
l
1, 2, 3 small
4, 5, 6* medium
7, 8, 9
large
1*
forwards, mounting height standard
2
forwards, mounting height high
3
backwards, mounting height standard
4
backwards, mounting height high
5
direction recognition OFF, mounting height standard
6
direction recognition OFF, mounting height high
The sensor can be configured in two ways:
→
With keys on the sensor (basic settings), chap. 5.1
→
With the remote control (complete setting options), chap. 5.2
General procedure
[>]
[<]
Field size: Press [<] and [>] for 2 s
Functionality: Press [<] and [>] for 4 s
Restore factory settings: Press [<] and [>] for 8 s
1)
Keep [<] and [>] pressed for a corresponding length of time; every 2 s the
green LED will flash once
2)
Frequency of the flashing green LED (1-9 times) indicates current parameter
level
3)
The parameter level can be decreased or increased with [<] and [>]
respectively
4)
Press [<] and [>] briefly to exit the programming mode (settings are saved)
4
Displays on the Sensor
Red LED = function indication
Green LED = status indication
3.4
Electrical connections
Important:
All other combinations are not permitted! A separate input must be available for
each Merkur 2 ES.SM.
F
/ Merkur 2 ES.SM.
V
if the door controller has a frequen-
cy or voltage input.
Combination of several Merkur 2 ES.SM for escape and rescue routes
According to AutSchR, signal sensors must fully release the escape route
without an explicit request, i.e. at any point across the full width of the door up
to at least 1.50 m before the door panels. This requires two sensors depending
on the door size. The following combination of two Merkur 2 ES.SM.R outputs is
the only approved option:
* Factory setting
RJ12
Connection type
Model
white
1
2
–
36
V DC
black
red
green
yellow
blue
U in +
U in –
not connected
F out
˜
+
12–36 V DC
–
12–28 V AC
U out +
U out –
+
12–36 V DC
–
12–28 V AC
not connected
not connected
white
black
red
green
yellow
blue
+ 12–36 V DC
– 12–28 V AC
white
black
red
green
yellow
blue
Merkur 2 ES.SM.F.C
Merkur 2 ES.SM.V.C
Merkur 2 ES.SM.R.C *
Merkur 2 ES.SM.F
Merkur 2 ES.SM.V
Plug-in screw terminal
1
2
–
36
V DC
U in +
U in –
F out
˜
+
12–36 V DC
–
U out
+
U out
–
+
12–36 V DC
–
12–28 V AC
not connected
1
2
3
4
5
brown
blue
black
white
1
2
3
4
5
Not available
brown
blue
black
white
Connect PIN 1 and 5 using a wire bridge
lights up
→
object is detected
dark
→
no object is detected
flashes
→
safety opening
(self-monitoring of the system)
lights up
→
SMD active
dark
→
SMD not active
5.1.1
Adjustable parameters
Le
ve
l
1
narrow field
2*
wide field
Field geometry: Press [<] and [>] for 6 s
Le
ve
l
Control unit with two
inputs for the
relay signal
Merkur 2 ES.SM.R.C
Merkur 2 ES.SM.R.C
Merkur 2 ES.SM.R.C
* Both relay contacts are electrically isolated. Connecting the two contacts in series or in parallel is not permitted for safety reasons. Each contact must be evaluated
separately by the door controller. The initial state is only correct if the state of both relay contacts is the same. The door controller has to periodically verify this relay
output function according to the relevant standards requirements.