6.4. Command Type Setting Command
STX 05 C n ETX
/Change the command type setting/
ASCII Format STX 05 C n ETX
Dec. Format [02][05][67] n [03]
Hex. Format [02h][05h][43h] n [03h] 30h n 37h
≦
≦
Description This command will change the command type and initialize
the display.
The display emulation mode is based on DSP800/ ESC/ ADM
787/ POS7301/ AEDEX/ UTC/ CD5220 mode.
n
Command Type
N
Command Type
30h
DSP-850
34h
AEDEX
31h
ESC/POS
35h
UTC/P
32h
ADM 787
36h
UTC/S
33h
DSP800
37h
CD5220