Scanning Mode
Good-read Off:
The trigger button
must be pressed to active scanning.
The light source of scanner stops
scanning when there is a successful
reading or no code is decoded after
the
S tand-by Timer
/
24 duration
elapsed. (Laser Model Default)
Momentary:
The trigger button acts
as a switch. Press button to active
scanning and release button stop
scanning.
Alternate:
The trigger button acts as a
toggle switch. Press button to active or
stop scanning.
Timeout Off:
The trigger button must
be pressed to active scanning, and
scanner stops scanning when no code
is decoded after the
Stand-by Timer
/
24 duration elapsed.(CCD Model
Default)
Timeout Flash:
The trigger button
must be pressed to keep scanning.
The scanner flashes the light source
when no code is decoded after the
S tand-by Timer
/
24 duration elapsed. This mode can save the
power resource and extend the operation life of the light source. The
scanner can be waked up when there is a successful reading or
trigger button to be pressed.
Continue:
The scanner always keeps reading, and no matter when
trigger button is pressed or duration is elapsed.
Test Only:
The scanner always keeps reading continuously and
same label reading is allowed without double confirm. The feature
can test the performance of scanner for reading speed and sensitive.
(Diagnostic mode)
Object Detect:
Wake up automaticlly without trigger switch, if an
object in the front of scanner is detected.(Some Laser Model Only)
*
For saving power and longer lift of laser component, all scanning
mode, the laser beam and motor will stop when no code is decoded.
Good-read Off
CAB
*CAB*
Momentry
CAC
*CAC*
Alternate
CAD
*CAD*
Timeout Off
CAE
*CAE*
Timeout Flash
CAF
*CAF*
Continue
CAG
*CAG*
Test Only
CAA
*CAA*
Object Detect
CAI
*CAI*
Spare
CAJ
*CAJ*
EXIT
System Control
*/$%END*
23