45
english
Fault
Cause
Remedy
Pump does not run
A fuse
Change fuse.
– red message light
in the electrical installation
is not lit
is defective.
– green message light
is not lit
The fault current safety switch
Turn the FI safety switch on again.
or fault voltage safety switch
has tripped.
The pump is defective.
Repair or replace the pump.
– green message light
The pump has been
1. Turn the pump back on
is lit
shut down in one
by pressing the key.
of the following ways:
2. Turn the pump back on
1. Via the key
with the R100 or
2. Via the R100
by pressing the key
3. Through the turning
3. Turn on the pump
of the external
with ON/OFF switch
ON/OFF switch*
4. Turn on the pump
4. Via the bus signal*
via the bus signal.*
* The malfunction can be temporarily repaired by adjusting the operating
setting to «MAX Characteristic Curve» on the pump control panel
or via the R100 unit, as in this case the external switching command
will be ignored.
The pump has been
Power supply error
check to see if voltage
shut down due to a fault.
is at the specified level
– red message light is lit
(e.g.) insufficient voltage).
– green message light
is not lit
Pump is blocked
Turn pump ON/OFF
and/or dirt in the pump.
several times.
Disassemble motor for deblocking:
Close slide valve in front of and
behind the pump.
Release 4 socket head screws.
Warning:
Hot water can run out.
Remove motor
Turn impeller until shaft
turns smoothly.
Refit motor and open slide valve.
Remove the locking screw
and try to turn the rotor using a
screwdriver inserted into the notch
at the end of the shaft.
If necessary,
disassemble and clean the pump.
Electronics malfunction
Please contact Biral
10. Summary of malfunctions
Switch off all poles of the supply voltage without fail
before removing the terminal box cover and always
before dismantling the pump.
The electronics can still be live for up to 10 minutes
after switching off the power supply!
See Section 7.5
Содержание A 1002
Страница 94: ...8 108 8 1 108 8 2 108 8 3 0 10 109 8 4 109 8 5 109 9 109 10 111 11 113 11 1 113 11 2 113 12 114 13 114 94...
Страница 95: ...DIN 4844 W8 DIN 4844 W9 1 1 1 1 2 1 3 1 4 95...
Страница 96: ...1 5 1 6 NIN CENELEC 1 7 1 8 1 9 96 2...
Страница 99: ...99 961338_00 4 5 961339_00 1 2 1 2...
Страница 100: ...100 4 7 75 C 0 6 95 C 1 0 110 C 1 7 500 0 01 100 95 C 0 45 110 C 1 10 961340_00 4 6 7 2...
Страница 103: ...103 5 8 6 3 A2 7 2 6 6 1 4 6 2 0 2...
Страница 104: ...104 6 4 Biral 6 4 1 A AD 1 10 2 L N 3 L N 4 L 1000 1500 L N 20 5 L N 6 L N 7 6 4 2 A 802 AD 802 A 1002 6 4 1...
Страница 105: ...105 7 1 A1 A1 2 A3 7 5 R100 3 R100 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 7...
Страница 106: ...106 2 1 6 2 3 4 7 2 A1 7 3 A2 3 3 7 4 H V 3 A 802 11 5 75 A 1002 11 5 75 AD 802 11 5 75 1P 105 2P...
Страница 107: ...107 t t 7 5 A3 7 6 A 802 A 1002 AD 802 A 802 KW A 1002 KW AD 802 KW 6 6 3 3 24...
Страница 108: ...108 8 8 1 R100 7 3 8 2 7 8 c R100...
Страница 109: ...109 8 3 0 10 0 10 5 6 2 1 2 3 4 8 4 1 2 3 4 1 3 4 2 3 4 3 4 5 0 10 5 6...
Страница 110: ...110 8 5 R100 R100 R100 R100 R100 9...
Страница 111: ...111 FI 1 2 1 R100 2 R100 3 3 4 4 R100 4 10 10 7 5...
Страница 112: ...112 Biral 7 3 6 2 12 7 3 6 2...
Страница 113: ...113 11 11 1 11 2 15 C 110 C B2 DIN 4102 A 802 WD 9 A 1002 WD 10...
Страница 115: ......