BIQU BIQU-Hurakan Скачать руководство пользователя страница 1

1 / 62

WWW.BIQU3D.COM

BIQU-Hurakan

User Manual V1.0

Содержание BIQU-Hurakan

Страница 1: ...1 62 WWW BIQU3D COM BIQU Hurakan User Manual V1 0...

Страница 2: ...Tuning of Nozzle Height 17 5 Printing Preparation 19 5 1 Cura Installation 19 5 2 Cura Slicer Setting 19 5 3 Cura Slicing 22 6 Printing 26 6 1 Print via a MicroSD Card 26 6 2 Print via WiFi Network 29...

Страница 3: ...3 62 WWW BIQU3D COM 1 Packing List Tools 1set Screw Accessories 1set BIQU Hurakan TF Card Card Reader 1set Nozzle 1pc Power Cord 1pc Filament for Test 50g Cable Ties 10pcs...

Страница 4: ...60 including flexible filament with 95A stiffness File Format G code Firmware Klipper Printing Method USB Drive LAN Controlled Slicing Software Supported Cura Repetier Host Simplify 3D Rated Voltage 1...

Страница 5: ...5 62 WWW BIQU3D COM 3 Installation Step 1 Remove the motor from the gantry M4X16 Flat Head Countersunk Screw 2pcs Lead Screw Sleeve 1pc Step 2 Put the X axis module on the gantry...

Страница 6: ...Z axis aluminum part If it is too tight or too loose the eccentric nut can be adjusted with a wrench so that the POM wheels on both sides of the Z axis do not shake and are not too tight Step 3 Insta...

Страница 7: ...7 62 WWW BIQU3D COM Step 4 Mount the gantry on the machine base M5X40 Socket Head Cap Screw 4pcs Step 5 Install the filament bracket...

Страница 8: ...place the filament bracket at the slot on the top and finally tighten the screw with a screwdriver The T nut will rotate slightly during the tightening process to make itself stuck in the aluminum pr...

Страница 9: ...l Extruder Motor Cable 6P Terminal with E Label Filament Runout Detection Module Cable 3P Terminal with E Label X axis Motor Cable 6P Terminal with X Label X axis Limit Switch Cable 3P Terminal with X...

Страница 10: ...abel Cable Ties for Cable Management In the image above install the terminal to the corresponding position Step 8 Install the PTFE tube PTFE Tube 1pc Push the PTFE tube in until it can no longer be in...

Страница 11: ...nd that the machine is too tight or too loose there is a shaking phenomenon during the movement you can adjust its tightness by adjusting the eccentric nuts of X Y and Z with a wrench Y axis Eccentric...

Страница 12: ...V marked on the switch corresponding to Household Voltage 100 120V Voltage Mode 230V Switch to left you will see 230V marked on the switch corresponding to Household Voltage 200 240V Before turning it...

Страница 13: ...is correct then power on the machine 4 3 Screen Introduction Reset Button Reset button for the motherboard control system Control Knob Enter and exit the control interface Up and down selection Coolin...

Страница 14: ...WWW BIQU3D COM 14 62 After the installation of the BIQU Hurakan is completed a platform leveling is required Tram the print bed with the following procedure Control Home All Manual Level Clear Mesh...

Страница 15: ...height of each corner of the print bed with the thumbscrew until you can feel slight resistance when moving the A4 paper back and forth Note this is not to adjust the nozzle height nozzle height will...

Страница 16: ...WWW BIQU3D COM 16 62...

Страница 17: ...whether the screws on the machine are installed correctly and make sure they are tight 4 6 Tuning of Nozzle Height Enter the secondary interface during printing Tune Offset Z 0 000 Adjust according to...

Страница 18: ...ht of the nozzle A right distance between the nozzle and the bed the filament sticks sufficiently well to the bed The nozzle is too high from the bed filament curls and does not lay around the nozzle...

Страница 19: ...nozzle or bed may be damaged 5 Printing Preparation 5 1 Cura Installation Link https ultimaker com software ultimaker cura Download install and open the latest version of Ultimaker Cura 5 2 Cura Slice...

Страница 20: ...WWW BIQU3D COM 20 62...

Страница 21: ...21 62 WWW BIQU3D COM...

Страница 22: ...WWW BIQU3D COM 22 62 5 3 Cura Slicing Drag and drop the model file you want to print into Cura...

Страница 23: ...23 62 WWW BIQU3D COM In the printer that you have set up slice the model using the stock settings or import your own settings if you are an advanced user click slice and save to your desired folder...

Страница 24: ...WWW BIQU3D COM 24 62...

Страница 25: ...25 62 WWW BIQU3D COM...

Страница 26: ...pen 1 The machine will freeze immediately 2 The installed OS on the MicroSD can be damaged and will need to be reflashed 3 MicroSD can be damaged and you will need a brand new high quality MicroSD car...

Страница 27: ...27 62 WWW BIQU3D COM Transfer the gcode into the gcode folder Step 2 Insert Micro SD and power the machine on again Step 3 Select the gcode file SD Card BB1_boat gcode Start Printing...

Страница 28: ...ated bed start to warm up and when the temperature reaches the preset temperature the machine starts printing The nozzle and heated bed will cool down after the print is finished remove the print afte...

Страница 29: ...nding IP address Step 1 Set the WIFI ssid and password Note your control device and the printer need to be connected to the same WiFi Make sure the machine is powered down remove the MicroSD card and...

Страница 30: ...word Save the file Note No setup is required if the printer is using a wired network Step 2 Insert the MicroSD card and power on the machine Click the rotary knob and scroll to the bottom to check the...

Страница 31: ...31 62 WWW BIQU3D COM Upload the gcode file Select the file and click print...

Страница 32: ...components reached the printing temperature 6 3 Print via a USB Drive Transfer the gcode file into the USB Drive folder Plug the USB drive into the corresponding port of the printer Select the gcode...

Страница 33: ...33 62 WWW BIQU3D COM The print will start after the components reached the printing temperature...

Страница 34: ...icroProbe factory offset is incorrect or you have rewritten the system the steps for calibration are as follows Setup Calibration Start Probing Move Z adjust the distance between the nozzle and bed 1m...

Страница 35: ...35 62 WWW BIQU3D COM Make sure the distance between the bed and the nozzle is between 0 and 0 1mm...

Страница 36: ...WWW BIQU3D COM 36 62 If Move Z cannot be adjusted you can adjust Test Z for more precise fine tuning...

Страница 37: ...37 62 WWW BIQU3D COM Make sure the distance between the bed and the nozzle is between 0 and 0 1mm Back to previous interface...

Страница 38: ...WWW BIQU3D COM 38 62 Accept Save then we can start auto leveling 7 2 Auto Leveling Control Bed Mesh Save...

Страница 39: ...39 62 WWW BIQU3D COM The running track of the printhead during bed mesh Wait for the finish the printer will automatically save the config and return to the main interface...

Страница 40: ...WWW BIQU3D COM 40 62 7 3 ON OFF of the Filament Runout Detection Module...

Страница 41: ...switch between two heating powers The red light is on for 100W Both the red and blue lights are on for 240W ADXL345 Interface RJ45 Interface USB Interface for USB Drive USB camera and other modules wi...

Страница 42: ...WWW BIQU3D COM 42 62...

Страница 43: ...43 62 WWW BIQU3D COM The default resolution of CURA is 32 32 you can adjust it according to the display effect Then use Cura to slice and upload to the web...

Страница 44: ...WWW BIQU3D COM 44 62 7 6 ADXL345 Resonance Compensation Calibration Install on X Axis Printhead Loosen the screw M3x6 securing the lower right corner of the printhead...

Страница 45: ...crew M3x6 1Pc ADXL345 Module 1Pc Install the fixing hole of the lower end of the ADXL345 module in the position where the screw was just removed Note the centerline of the two fixing holes of the ADXL...

Страница 46: ...WWW BIQU3D COM 46 62 platform Centerline of the Two Fixed Holes of the ADXL345 Module Adjust the position and fix it with M3x6 screws...

Страница 47: ...47 62 WWW BIQU3D COM Wiring ADXL345 Cable 1Pc ADXL345 Module Interface ADXL345 Interface on Printer Connect the ADXL345 Module with the printer with the ADXL345 Cable...

Страница 48: ...WWW BIQU3D COM 48 62...

Страница 49: ...ng_Resonances html Note The printer needs to be Home before calibration Enter the X axis calibration command at the command line SHAPER_CALIBRATE AXIS X Note it will vibrate in the X axis at this time...

Страница 50: ...WWW BIQU3D COM 50 62 The test can be aborted in case of emergency After calibration enter the save code SAVE_CONFIG Then power off the printer and remove the ADXL345 module...

Страница 51: ...ated Bed Loosen the screw M3x10 on the left side of the heated bed cable plastic part Phillips Flat Head Countersunk Screw M3x10 1Pc Heated Bed Cable Plastic Part 1Pc ADXL345 Module 1Pc Centerline of...

Страница 52: ...fixing hole of the ADXL345 module in the position where you just removed the screws Note the centerline of the two fixed holes of the ADXL345 module should be perpendicular to the Y axis Adjust the p...

Страница 53: ...53 62 WWW BIQU3D COM...

Страница 54: ...WWW BIQU3D COM 54 62 Wiring ADXL345 Cable 1Pc ADXL345 Interface on Printer ADXL345 Module Interface Connect the ADXL345 Module with the printer with the ADXL345 Cable...

Страница 55: ...OM Y Axis Calibration Note The printer needs to be Home before calibration Enter the Y axis calibration command at the command line SHAPER_CALIBRATE AXIS Y Note it will vibrate in the Y axis at this t...

Страница 56: ...6 62 the printer first to ensure that the vibration is not too strong After calibration enter the save code SAVE_CONFIG Then turn off the printer remove the ADXL345 module and restart the printer to f...

Страница 57: ...ence power supply of the stepper motor can be adjusted appropriately to adjust the output current Overheating of the motor motor driver or power supply indirectly affects the movement of the nozzle Qu...

Страница 58: ...use the pliers to make the filament tip pointy The filament drive gear is too tight adjust it to make an appropriate tightness There is residue in the heat break Please preheat it to 230 then push and...

Страница 59: ...f the filament changes resulting in insufficient supply Make sure the machine is running Question 4 Warping Answer 4 The distance between the nozzle and the bed is too far adjust the distance The cool...

Страница 60: ...swer 7 It may be that the nozzle is blocked use a needle to unclog it The quality of the filament is not high you can try another filament The temperature of the printing head is too high and the fila...

Страница 61: ...tance by 1mm and test again to see if the performance improves Check the retraction speed Retraction works best between 20 and 100mm s In order to set the most ideal value it is necessary to set diffe...

Страница 62: ...hand into the machine when the printer is working to avoid being pinched 5 The machine must not be used for more than 100 hours for a long time to avoid damage to the parts due to overheating 6 Minor...