background image

1

A  Intended Use (pg. 2)
B  Important Safety Instructions (pg. 2)
C  Getting Started (pg. 3)
D  Your BioTel Care BGM™ (pg. 5)

D.1  Testing Your Blood Glucose (pg. 10)

D.2  Testing With Control Solution (pg. 17)

D.3  Functions and Settings (pg. 21)

E  Classic Mode (pg. 31)

E.1  Testing Your Blood Glucose (pg. 32)

E.2  View Your History on the Meter (pg. 35)

E.3  Testing With Control Solution (pg. 35)

E.4  Setting Up Your BioTel Care BGM™ (pg. 39)

F  Maintenance of Your BioTel Care BGM™ 

and Lancing Device (pg. 40)

G  Storing Your BioTel Care BGM™ and Test Strips (pg. 45)
H  Troubleshooting (pg. 45)

About Your System (pg. 50)

J     Terms of Service/Use (pg. 55)

K    Privacy Policy (pg. 69)

Contents

Blood Glucose 

Monitoring System

 

User Manual

This product contains a rechargeable internal battery. To conserve 

battery power this product will turn off the screen after one 

minute of non-use. To turn on the product either insert a test strip 

or press any side button.

TM

ART-161 Rev. 6

Not Intended for Sale Within the EU

Содержание BGM

Страница 1: ...p Your BioTel Care BGM pg 39 F Maintenance of Your BioTel Care BGM and Lancing Device pg 40 G Storing Your BioTel Care BGM and Test Strips pg 45 H Troubleshooting pg 45 I About Your System pg 50 J Terms of Service Use pg 55 K Privacy Policy pg 69 Contents Blood Glucose Monitoring System User Manual This product contains a rechargeable internal battery To conserve battery power this product will tu...

Страница 2: ... the diagnosis or screening of diabetes or for neonatal use Palm and forearm testing should be done only during steady state times when glucose is not changing rapidly The BioTel CareTM Blood Glucose Meter uses cellular data transmission to send test results to Telcare s remote database Telserve and to receive messages from Telserve The BioTel CareTM Blood Glucose Monitoring System is not intended...

Страница 3: ...224025 htm CDC Clinical Reminder Use of Fingerstick Devices on More than One Person Poses Risk for Transmitting Bloodborne Pathogens 2010 http www cdc gov injectionsafety Fingerstick DevicesBGM html Protection of Laboratory Workers from Occupationally Acquired Infections Approved Guideline Third Edition Clinical and Laboratory Standards Institute CLSI document M29 A3 ISBN 1 56238 567 4 All images ...

Страница 4: ...new meter Make sure you charge your glucose meter for at least 6 hours before first use To charge your glucose meter use the AC Charger included in your kit Important Please remove the protective film over the screen Please wait for the meter to finish the boot process to start a test when it powers on You should use the BioTel Care BGMTM for Testing Blood Glucose Testing only with fresh capillary...

Страница 5: ...reen Long press of power button when screen is on pops out a window with the following options Power Off Restart and Airplane Mode Silent Vibrate and Sound UP Down Buttons to scroll through menus Enter Button Display Touch Screen Insert Test Strip white side up Battery Access Notch Use the notch to remove the battery cover and replace the battery Home button ...

Страница 6: ...it easy after a few attempts Check the expiration date printed on the test strip bottle and its package DO NOT use expired test strips Use each test strip immediately after removing it from the bottle Do not use wet or damaged test strips Wash your hands and testing site thoroughly with warm water and soap Dry your hands well Test in a place where the temperature range is between 50 F 10 C and 104...

Страница 7: ...molar state with or without ketosis Critically ill patients should not be tested with blood glucose meters FOLLOW THESE IMPORTANT SAFETY GUIDELINES Please follow cleaning and disinfecting instructions for the meter and lancing device to prevent the risk of blood borne pathogen transmission Follow any cleaning disinfection instructions that may come with the lancing device you use The meter and lan...

Страница 8: ...nal Strength Battery Level Current Time Last Test Reading Date and Time of Last Reading In this Home Screen swipe up down OR use the UP DOWN buttons located on the left of your meter to access the meter s options Test Mode Logs Summary Messages Support Settings Apps Reminders ...

Страница 9: ...es the battery is getting low and needs to be charged Indicates the strength of the wireless signal between base station and the meter in a manner familiar to most users Additional bars of signal depict increased signal strength The user manual instructs users that two bars or less of signal may result in unreliable transmission and reception of data The 3G or 1X icon may be displayed with the wir...

Страница 10: ... when charging is shut off because battery temperature is too high low D 1 Testing Your Blood Glucose 1 Power on the BioTel Care BGMTM with the PWR Power button on the right side of the BGM Long press if it is in OFF mode short press if it is in SLEEP mode The device will automatically display the Home Screen 2 Press on the TEST MODE icon OR use the three buttons on the left side of the BGM to ent...

Страница 11: ...er a code from the vial BioTel CareTM and Telcare strips do not require a code 4 Firmly insert the test strip into your BioTel Care BGMTM until it is fully seated The strip port light will turn on 5 Prepare Your Lancing Device Refer to Components Illustration 5 1 Remove the lancing device cap f by snapping it off at an angle 5 2 Insert a new lancet h into the lancet holder e This action will cock ...

Страница 12: ...lancet Firmly pull the lancet away from the device 5 9 The lancet should be removed and disposed in accordance with local waste regulations Important Information for Lancing Device Use the BioTel CareTM or Telcare Lancing Device included in your BioTel CareTM Blood Glucose Monitoring System to obtain a blood sample The minimum blood sample volume is 0 8 microliters Purchase an additional BioTel Ca...

Страница 13: ...ainst the side of the fingertip Press the trigger button and then lift the lancing device away from the finger after the puncture is complete 6 Testing Using an Alternate Test Site This package does NOT include an alternate site cap If you require one please contact Telcare LLC Important Information on Alternate Site Testing You BioTel Care BGMTM is capable of testing your blood glucose from your ...

Страница 14: ...hair or bone Vigorously rub the side of your palm with your other hand for at least 10 seconds You should feel it get quite warm Press the opening of the clear cap against a fleshy area of the palm Press the lancing device up and down in a slow pumping motion for several seconds to help the flow of blood Keep steady pressure on the area and press the release button Do not be afraid to apply pressu...

Страница 15: ...NUE button OR use the ENTER key to confirm Your test result will be automatically stored into the meter history If a Reading Tag is not selected in the allotted time it will automatically be tagged as No tag 9 Sending Your Results After pressing the CONTINUE button your BioTel Care BGMTM will send the results to Telcare s secure server 10 Remove the used test strip and discard it properly CLINICAL...

Страница 16: ...ot communicate with the server the following message will appear No network connection Reading will be sent when a connection returns Your test results will be stored in your device You can send the reading on your own by going into Logs from the main menu For the transmission to be successful network connection is required The meter will attempt to forward unsent readings automatically Readings t...

Страница 17: ... using your fingertip If you still get a high or low reading contact your doctor immediately References 1 American Diabetes Association Standards of Medical Care in Diabetes 2008 Diabetes Care 2008 31 S12 S54 D 2 Testing With Control Solution Control solution testing will confirm that your BioTel Care BGMTM and Test Strips are working properly You should perform control solution testing when Using...

Страница 18: ... buttons on the left side of the BGM to enter Test Mode Switch modes from Normal Test Mode to L1 Control Solution Mode To test Level 1 L1 control solution press on the L1 CONTROL button OR use the UP DOWN buttons to highlight L1 CONTROL button Step by Step Guide to Control Solution Testing Purchase additional control solution by calling Telcare LLC at 888 666 4530 US or 1 978 610 4688 Internationa...

Страница 19: ...ort light will turn on The term BioTel Care or Telcare should be facing up The sample tip should be facing up Continue to push the strip in until Apply Level 1 2 Control Solution appears Do not touch the sample tip 5 Use Level 1 solution for L1 mode Use Level 2 solution for L2 mode Squeeze a drop of control solution onto a clean dry non absorbent surface Immediately replace the bottle cap on the c...

Страница 20: ...olution 1 Only use BioTel CareTM or Telcare Glucose Control Solution with the BioTel CareTM or Telcare Test Strips Other brands of control solution or test strips may produce inaccurate results 2 Always check the expiration date DO NOT use expired control solution 3 DO NOT FREEZE Store the control solution at room temperature 4 Never touch the tip of the control solution bottle to the test strip I...

Страница 21: ...ose tests until you resolve this issue D 3 Functions and Settings View Your Logs on the Meter View your logs on your meter Your BioTel Care BGMTM can store a lifetime of logs Each log is stored with date and time 1 Power on the BioTel Care BGMTM by using the PWR button 2 Press on the LOGS icon OR use the UP DOWN ENTER buttons to access logs 3 Swipe up down OR use the UP DOWN buttons to scroll thro...

Страница 22: ... Solution and other Logs Control solution logs are displayed in a grey circular box Non Glucose logs are displayed in a grey rectangular box Add Logs on the Meter Add your logs on your meter Your BioTel Care BGMTM allows you to manually add Blood Glucose Carbs Medicine Activity Weight Blood Pressure and A1C 1 You can enter the Add Log mode from the Logs Screen or Home Screen by pressing on the Add...

Страница 23: ...g and timestamp and press SUBMIT to save and upload this log to the server 5 Create New Log Type You can enter the Create New Log Type screen by pressing the New Log Type button where you can enter new type name and unit 6 Press SAVE to save the log type ...

Страница 24: ...use the buttons to select and enter 2 You can swipe up down OR use the UP DOWN buttons to navigate through each message 3 To return to the Home Screen press the BACK or HOME button Summary of Past Readings Display statistics of your past readings on your meter Your BioTel Care BGMTM allows you to check the statistic result of your past blood glucose readings The summary screen has 5 graphs Persona...

Страница 25: ...n or use the buttons to select and enter 2 You can swipe left right press the and icons OR use the UP DOWN buttons to navigate to each graph 3 You can also select one of the following timeframes to generate the graph Today 7 14 30 90 days All 4 To return to the Home Screen press the BACK or HOME button ...

Страница 26: ...enter 2 You can create a new reminder by pressing the CREATE REMINDER button You can edit an existing reminder by pressing on it this will bring up the reminder detailed information In the detailed information you can change the time title and days which the reminder are active by pressing on each area Pressing the SAVE button saves the reminder setting Pressing the DELETE REMINDER button deletes ...

Страница 27: ... the SUPPORT icon or use the buttons to select and enter 2 You can open a page by page slideshow of the user manual by pressing the VIEW button OR use the UP DOWN buttons to highlight user manual and then press the ENTER button You can swipe up down and press on the video tutorial you want to watch OR use the UP DOWN buttons to highlight the video and then press the ENTER button 3 To return to the...

Страница 28: ...ttings option 3 Press on the SETTINGS icon or use the ENTER button to enter the Settings Menu Setting Up Your BioTel Care BGMTM Your BioTel Care BGMTM time is automatically updated with the local date and time when a cellular connection is established If you would like to view your meter s preset settings navigate to the Settings screen ...

Страница 29: ... meter will reset the time from the new network Languages Change the language displayed by your meter Time Format Change the time display as 24 hour or 12 hour Setting Options Volume Change the volume of your meter by moving the slider thumb Brightness Change the brightness of your meter s screen Date Format Change the date display format Tag Timeout BG tag timeout determines the duration of the t...

Страница 30: ...ormation Press here to check the current software versions Download software updates for your BGM from the App Store Your BioTel Care BGMTM allows you to download software updates available for your BGM from the App Store You can enter the Apps Screen from the Home Screen by swiping up and pressing the APPS icon or use the buttons to select and enter Apps Critical Updates When a critical software ...

Страница 31: ...t again after 24 hours until the update has been completed E Classic Mode You can select the Classic Mode under the Mode option on the Settings screen and the Classic style main menu screen will be displayed It mimics the User Interface in Telcare s previous models Main Menu In this Home Screen swipe up down OR use the UP DOWN buttons located on the left of your meter to access the meter s options...

Страница 32: ...re BGMTM until it is fully seated 4 Prepare Your Lancing Device Please see asterisk on Page 33 On the Test Mode Screen you can see the following Wireless Signal Strength Battery Level Current Time Date and Time of Last Reading Last Test Reading 1 Power on the BioTel Care BGMTM device with the PWR button on right side of meter The device will automatically start in the Main Menu Select Test Mode to...

Страница 33: ... 8 Tagging Your Data The screen will start to count down After 6 seconds your glucose level will appear on the display screen Your test result will be automatically stored into the meter history If a Reading Tag is not selected in the allotted time it will automatically be tagged as No tag 9 Sending Your Results As soon as you select the tag your BioTel Care BGM will send the results to Telcare s ...

Страница 34: ...ful data transmissions to the server you may receive a multiple choice question to answer This may be a question from your caregiver or relate to reordering supplies Swipe up down OR use the UP DOWN buttons to select the appropriate answer Press on the option OR use the ENTER button to transmit CLINICAL RESPONSE SCREEN After data transmission you will see a graph that compares your reading to your...

Страница 35: ...ol Solution Control solution testing will confirm that your BioTel Care BGMTM and Test Strips are working properly You should perform control solution testing when Using the meter for the first time Using a new bottle of test strips You left the test strip bottle cap open You dropped the meter You suspect the meter and test strip are not working properly The test results do not reflect how you fee...

Страница 36: ... on the left side of the BGM Switch modes from Normal Test Mode to L1 Control Solution Mode To test Level 1 L1 control solution use the UP DOWN buttons to highlight L1 mode Press the middle ENTER button to select L1 mode Upon successful completion of Level 1 L1 test Level 2 L2 control solution Again use the UP DOWN keys on the left side of the BGM to access the main menu Switch modes from Normal T...

Страница 37: ...ld be facing up Continue to push the strip in until Apply Level 1 2 Control Solution appears Do not touch the sample tip 6 Use Level 1 solution for L1 mode Use Level 2 solution for L2 mode Squeeze a drop of control solution onto a clean dry non absorbant surface Immediately replace the bottle cap on the control solution bottle Do not apply control solution to the test strip directly from the bottl...

Страница 38: ...trol Solution readings are stored on the meter but are not transmitted and displayed on the server Important Tips About Control Solution 1 Only use BioTel CareTM Glucose Control Solution with the BioTel CareTM Test Strips The BioTel Care BGMTM is also compatible with the Telcare Glucose Control Solution and Telcare Test Strips Other brands of control solution or test strips may produce inaccurate ...

Страница 39: ...te up to 3 alarms to help remind yourself when to test next Date and Time This page allows you to view the Date and Time settings of your device Volume This page allows you to select the volume of your meter Use the UP DOWN keys to select the appropriate volume Brightness Change the brightness of your meter s screen Languages Change the language displayed by your meter BG Tag Timeout BG tag timeou...

Страница 40: ... button to enter it When you are done entering your Name press the ENTER button again after entering the last character About This screen provides a listing of current software and related information about your meter This is helpful if you need technical support F Maintenance of Your BioTel Care BGMTM and Lancing Device Charging Your BioTel Care BGMTM Your BioTel Care BGMTM uses a rechargeable ba...

Страница 41: ... button on your battery may not be fully charged If after 6 hours of charging the device the device does not turn on contact Telcare technical support at 888 666 4530 or 1 978 610 4688 International Warning Please only use the included charger to charge your meter other chargers may result in excessive heating of the device Please call customer support if you feel the meter is heating up significa...

Страница 42: ...ean and disinfect your device While surfaces may look clean many infectious germs may be lurking around Some germs can live on surfaces for hours and even for days The disinfection process shown in the pages that follow is effective in destroying dangerous Hepatitis B viruses If the device is being operated by a second person who is providing testing assistance to the user the meter should be disi...

Страница 43: ...r 1 825 cleaning and disinfection cycles Please obtain a new meter after cleaning and disinfecting the meter 1 825 times or once the lifetime of the meter 5 years has been reached whichever comes first Meter Cleaning Dos and Don ts Do not allow cleaning solution to run in or around the strip port Doing so may cause a malfunction Do not let the meter come in contact with water Do not use any glass ...

Страница 44: ... rinse Store lancing device in carry case or in a clean and dry environment IMPORTANT LANCING SAFETY MEASURES If the lancing device is being operated by a second person who is providing testing assistance to the user the lancing device and endcap should ALWAYS be disinfected prior to assistance from the second person Stop using the lancing device and contact customer service immediately for a repl...

Страница 45: ...in the bathroom or kitchen Immediately close the bottle cap tightly after removing a test strip Do not attempt to open the meter Opening the meter will void the warranty and may cause it to operate improperly If you have technical problems or questions turn your meter off and contact Telcare at 888 666 4530 US or 1 978 610 4688 International Support is available Monday through Friday 9AM 9PM EST D...

Страница 46: ... to give a reliable reading Action to take Remove the test strip and repeat the test with a new test strip 4 Error Message The temperature of the environment is too high or The temperature of the environment is too low What it means The meter is too hot or too cold Action to take Move the meter into an area that is between 50 F 10 C and 104 F 40 C After receiving this error allow the meter to be a...

Страница 47: ...tion of data The strength indicator is located at the top right of the meter s screen 3 Message High Displayed What it means If you see High displayed on your device your blood sugar level may be out of range in excess of 600 mg dL High Action to take See Troubleshooting pg 45 and wash your hands Dry your hands completely Test again using fingertip testing DO NOT test on your palm or forearm If yo...

Страница 48: ...Two bars or less of wireless signal strength may result in unreliable transmission and reception of data Restart meter and send reading within Logs If your meter has had an extended period of inactivity or excessive data usage for ancillary applications your cellular service may have been discontinued in accordance with the Telcare Terms of Service Contact Telcare Technical Support for re activati...

Страница 49: ...ievable devices are also specifically excluded from this warranty Transfer of ownership will render this warranty null and void Please direct any questions or claims to the authorized dealer from whom you purchased your system or to Telcare LLC 150 Baker Ave Extension Suite 300 Concord MA 01742 USA Phone 888 666 4530 US or 1 978 610 4688 International This warranty applies only to the original pur...

Страница 50: ...Sleep Mode After 1 minute of nonuse 2 minutes for Apply Blood Operating Temperature 50 F 104 F 10 C 40 C Relative Humidity Less than 85 Storage Conditions Meter at 39 F 122 F 4 C 50 C Test Strips at 39 F 86 F 4 C 30 C Control Solution at 39 F 86 F 4 C 30 C I About Your System Contact Telcare LLC Telcare LLC 150 Baker Ave Extension Suite 300 Concord MA 01742 USA Phone 888 666 4530 US or 1 978 610 4...

Страница 51: ...3 en and The National Cancer Institute NCI at http www cancer gov publications blogs newsletters cancer bulletin In the event that you are concerned about possible health effects the FDA suggests that you limit your own or your children s radio frequency RF exposure by limiting the length of your calls or by using hands free devices Implanted Medical Devices To avoid potential interference manufac...

Страница 52: ...FCC 47 CFR Part 2 22 H 24 E FCC Part 15 Subpart B ANSI TIA EIA 603 C 2004 FCC KDB 971168 D01 Power Meas License Digital Systems v01 This device functions on CDMA 2000 BC0 850mHz and BC1 1900mHz and uses CDMA 2000 1x and EVDO The following are operating characteristics of the BioTel Care BGMTM Effective RF Radiated Power Output and Operating Range Less than 24 dBm Modulation QPSK Quadrature Phase S...

Страница 53: ...nterruption IEC 61000 4 11 0 70 of Ut Complies FCC Interference Statement Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 18 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment comp...

Страница 54: ...tured not to exceed the emission limits for exposure to radio frequency RF energy set by the Federal Communications Commission of the U S Government The exposure standard for wireless mobile devices employs a unit of measurement known as the Specific Absorption Rate or SAR The SAR limit set by the FCC is 1 6W kg Tests for SAR are conducted using standard operating positions accepted by the FCC wit...

Страница 55: ...he FCC RF exposure guidelines for use with an accessory that contains no metal and that positions the handset a minimum of 1 5 cm from the body Use of other accessories may not ensure compliance with FCC RF exposure guidelines If you do not use a body worn accessory and are not holding the device at the ear position the handset a minimum of 1 5 cm from your body when the device is switched on J Te...

Страница 56: ...uires that you are either a a diagnosed patient of the particular community you are joining b a caregiver for a patient eligible to join such community c a health care professional e g doctor nurse health researcher etc e registered user for forum pages f registered e commerce user or d a guest as authorized by a Telcare employee The Sites and the Services Do Not Provide Medical Advice ALL OF THE ...

Страница 57: ... not post or upload any information or other content on the Sites that a is false inaccurate or misleading b is obscene or indecent c infringes any copyright patent trademark trade secret or other proprietary rights or rights of publicity or privacy of any party or d is defamatory libelous threatening abusive hateful or contains pornography Members shall not interfere with other members use and en...

Страница 58: ...out our members to facilitate the sending of unsolicited bulk communications such as SPAM or SPIM or allow others use of your membership account to take such actions Non Commercial Use by Members The member area of the Sites and the Service the Member Area and the content and information contained in such Member Area is for the personal use of individual members only and may not be used in connect...

Страница 59: ...y alerts and our selected partners if you do not wish to receive these kinds of communications you may choose to opt out by updating your profile h link or combine your information with other personal information we get from third parties to help understand your needs and provide you with better service and i to comply with our obligations under applicable laws and regulations As part of the Servi...

Страница 60: ... is not Protected Health Information PHI and is not subject to the privacy restrictions of HIPAA and any and all related privacy regulations Without limiting Telcare s obligation to preserve the confidentiality of your PHI Telcare may use your De Identified Information for statistical analytical and any academic or commercial purposes on an aggregated basis Telcare shall not use or disclose the De...

Страница 61: ...ou agree not to disclose to any person or entity personally identifiable information about other members that you learn using the Sites or the Service whether posted in the Member Area by a member or emailed to you by a member without the express consent of such member You may disclose information of a general nature that could not identify the member who provided such information or whom such inf...

Страница 62: ...tivity or excessive data usage for ancillary applications Telcare has no obligation to maintain store or transfer to you information or data that you have posted on or uploaded to the Member Area Modifications to this Agreement Telcare may update this Agreement at its sole discretion at any time and without prior notice by posting amended terms on the Sites Any use of the Meter Sites and the Servi...

Страница 63: ...ices offered on the Sites or to the applicable prices for any such products or services at any time without notice The materials and content on the Sites with respect to products and services may be out of date and Telcare makes no commitment to update the materials or content on the Sites with respect to such products and services The Company reserves the right to revoke any stated offer and to c...

Страница 64: ...ght to reject any order you place with us and or to limit quantities on any order without giving any reason If we reject your order we will attempt to notify you using the e mail address you have given us with the order Your credit or debit card will normally not be charged if we reject an order but we will process a refund if the charge has been made against your card Order Acceptance Confirmatio...

Страница 65: ...ty and will be shipped according to Company shipping policies In the rare event that your order never arrives notification of lost items must be received within 60 days from receipt of the shipping confirmation e mail Please review the Shipping page for additional information on shipping times rates and policies Disclaimer of Warranties THE SITES THEIR APPLICABLE CONTENT THE METER AND SERVICES ARE...

Страница 66: ...THE SERVICES Indemnification You agree to indemnify and hold harmless the Company its officers employees agents subsidiaries affiliates and other partners from and against any claims actions or demands liabilities and settlements including without limitation reasonable legal and accounting fees resulting from or alleged to result from your violation of this Agreement International Users Telcare ma...

Страница 67: ...risdiction of the state and federal courts sitting in the state of Delaware Miscellaneous Terms Telcare and the Telcare logo are trademarks of Telcare LLC You agree not to display or use these trademarks in any manner without a prior written permission from Telcare Telcare may assign this Agreement at any time to a subsidiary or parent company or to a successor to its business as part of a merger ...

Страница 68: ...t violations of this Agreement contact us at Telcare LLC 150 Baker Avenue Extension Suite 300 Concord MA 01742 888 666 4530 support telcare com IF YOU DO NOT AGREE TO THE TERMS AND CONDITIONS OF THIS AGREEMENT PLEASE DO NOT OPEN OR USE THE METER AND PROMPTLY CONTACT TELCARE SUPPORT EITHER AT THE EMAIL OR ADDRESS PROVIDED ABOVE ...

Страница 69: ...is policy Services This policy does not cover websites applications or services displaying different privacy statements 1 What information do we collect Information you provide us When you order we ask you for your name email address postal addresses telephone number and credit card information so that we can complete the transaction When you register for a mobile application we ask for informatio...

Страница 70: ...cation including pages you view Information we receive from third parties We may also collect additional information about you from third parties in providing you with the Services 2 How do we use the information we collect We use personal information collected through our Services for purposes described in this Policy or disclosed to you in our Services For example we may use your information to ...

Страница 71: ...opriate measures to protect the information that we receive about you from unauthorized access disclosure alteration or destruction No method of transmission over the Internet or electronic storage is 100 secure as a result we cannot guarantee absolute security 4 Will Telcare share the information it collects with others Telcare may share aggregated or de identified information such as statistics ...

Страница 72: ...lving sale or transfer of all or a portion of our business or assets to another company when such use is permitted by law 5 What access does Telcare give you to your personal information You may amend any inaccuracies or update your Telcare profile including your personal information and email preferences at any time You have the option of correcting updating and or changing contact and demographi...

Страница 73: ...kies but you can usually change your browser settings to remove or reject cookies Disabling cookies in your browser however may prevent access to some features of our website If you register with our Service we may elect to associate your information with our cookies to provide you with more customized content and enhanced functionality of our Services We may also collect information using Web bea...

Страница 74: ...e Privacy Policy is subject to change at any time Please check the webpage www telcare com for changes from time to time to make sure you are aware of our latest privacy practices If we make any changes to this Policy we will change the Last Updated date 9 How to send us feedback Our goal is to respect your privacy and we encourage user feedback to help us improve our privacy policies If you have ...

Отзывы: