![Biostar P4 TDG Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/biostar/p4-tdg/p4-tdg_engineering-validation-test-report_2755691067.webp)
67
V
CORE
OCP & OVP TEST-Ver0.90
Test
Environment
M/B TDG/0.90
Power
Supply
ST-300BLV
VID Setting
1.75
PWM
Hip 6302
Electronic Loading
Chroma 63030
Engineer Signature
Panda
O.C.P test
Over 60A
Pass/Fail
Pass
O.V.P test
2.18
Pass/Fail
Pass
V
CORE
OCP & OVP TEST-Ver0.91
Test Environment
M/B
TDG/0.91
Power Supply
DELTA DPS-300KB
VID Setting
1.75
PWM
Hip 6302
Electronic Loading
Chroma 63030
Engineer Signature
Panda
O.C.P test
Over 60A
Pass/Fail
Pass
O.V.P test
2.28
Pass/Fail
Pass
V
CORE
OCP & OVP TEST-Ver0.93
Test Environment
M/B
TDG/0.91
Power Supply
DELTA DPS-300KB
VID Setting
1.75
PWM
Hip 6302
Electronic Loading
Chroma 63030
Engineer Signature
Panda
O.C.P test
Over 60A
Pass/Fail
Pass
O.V.P test
2.28
Pass/Fail
Pass
V
CORE
OCP & OVP TEST-Ver1.0
Test Environment
M/B
TDG/1.0
Power Supply
DELTA DPS-300KB
VID Setting
1.75
PWM
Hip 6302
Electronic Loading
Chroma 63030
Engineer Signature
Panda
O.C.P test
Over 60A
Pass/Fail
Pass
O.V.P test
2.28
Pass/Fail
Pass