![Biostar P4 TDG Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/biostar/p4-tdg/p4-tdg_engineering-validation-test-report_2755691057.webp)
57
Transient Min (mV) at pins AC14/AC15
Load Step
Current
Measurement
Units
0A to 0A
0
12.60
mV
0A to 10A
10
33.20
mV
0A to 20A
20
75.20
mV
0A to 30A
30
87.00
mV
0A to 40A
40
141.00
mV
0A to 50A
50
147.00
mV
0A to 60A
60
180.00
mV
Transient Max (mV) at pins AC14/AC15
Load Step
Current
Measurement
Units
60A to 0A
0
199.00
mV
60A to 10A
10
154.00
mV
60A to 20A
20
146.00
mV
60A to 30A
30
85.00
mV
60A to 40A
40
61.20
mV
60A to 50A
50
29.20
mV
60A to 60A
60
7.60
mV