Biospace InBody 720 Скачать руководство пользователя страница 16

(2) Control & Connection Unit 

This unit allows the equipment to connect to peripherals such as computers 
and printers as well as transferring data back and forth. 

9pin Serial Port, Male (RS-232C)

Com 1 port is used to connect to the personal computer that runs the Lookin Body. 

Com 2 port is used for an additional peripheral. 

Com 3 port is used to hook up the automatic blood pressure monitor provided by the Biospace.

LAN Port (10/100 Base-T)

Through LAN cable, the equipment can communicate with the external systems including

computers. The LAN interface supports both 10Mbps and 100Mbps Ethernet connection.

USB Port (Version 1.1)

InBody720 communicates with external devices such as computers and printers through

the two USB ports and cables. You can use either of the two USB ports 

interchangeably. As of now, the equipment supports only printers as a USB device

25pin Parallel Port (IEEE 1284)

The 25pin parallel port is used to connect to printer. If you intend to use USB printer, 

connect it to the USB port.

Only the peripherals provided by Biospace can be connected to InBody720. For any inquiry about
peripherals, contact Biospace. 

Содержание InBody 720

Страница 1: ...User s Manual...

Страница 2: ...g Gangnam gu Seoul 135 784 KOREA TEL 82 2 501 3939 FAX 82 2 501 3978 Homepage http www biospace co kr E mail biospace biospace co kr Biospace InBody Salus Lookin Body are the registered trademarks of...

Страница 3: ...if you experience any inconvenience when using the equipment Forward any clinical inquiries at E mail biospace biospace co kr TEL 82 2 501 3939 6 Read signs of warning precautions and notes carefully...

Страница 4: ...equipment 2 To prevent fire caused by electricity always use the standard fuse 3 To avoid electric shock be sure to avoid contact between InBody720 and any kind of external connector or other device t...

Страница 5: ...n for operating InBody720 1 This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to oth...

Страница 6: ...00Base T USB port Version 1 1 IEEE 1284 25pin Parallel Female PCL 3 or above printer B Safety signs Dangerous high voltage Danger Warning Caution Note refer to the safety information Fuse specificatio...

Страница 7: ...the experience and technicality accumulated over the last 10 years Biospace released the InBody720 taking the body composition analysis to a new height The body composition analyzer InBody720 is accur...

Страница 8: ...on Getting Started 2 4 4 Initial Screen and Input 2 6 5 Personal Profile 2 7 6 Proper Posture 2 9 7 How to Operate the Equipment 2 11 8 Results 2 14 Chapter 3 Setup Establishment 1 Setup Menu 3 2 2 Qu...

Страница 9: ...1 Contents in a Carton 2 Exterior and Functions 3 Installation Instructions 4 Transportation 5 Repacking 6 Maintenance Chapter 1 Installation and Maintenance...

Страница 10: ...ur products include all the units A Product units InBody720 equipment Hinge cover pentagonal wrench 6mm 1 each Fuse holder 1 unit fuse F2 5AL250V 2 units spare fuse 4 units Cables AC 250V 10A 1 8m The...

Страница 11: ...ctrode bag 2 units Fixed string 2 units Head pad 2 units Hinge pad 2 units Accessory bag 1 unit To reduce the physical impact on the equipment use the wrapping material provided by the Biospace during...

Страница 12: ...s This section introduces the name of parts and their functions Before installation check for cracks on the case of equipment A Control Part B Upper Part C Lower Part D Rear Part Control Part Upper Pa...

Страница 13: ...part Hand Electrode Holder Place the hand electrode while not in use Thumb Electrode This is the area where the patients press their thumb on to come into contact with electricity during testing Palm...

Страница 14: ...he area connecting the upper and lower part of the equipment It can come off the equipment and be folded into half for easy transportation A body wrench 6mm is attached underneath the hinge cover Leve...

Страница 15: ...ot responsible for damages done on the product or injury caused by the user s unauthorized opening of the back cover Biospace is not responding to any request for repair or upgrade when damage is done...

Страница 16: ...pment can communicate with the external systems including computers The LAN interface supports both 10Mbps and 100Mbps Ethernet connection USB Port Version 1 1 InBody720 communicates with external dev...

Страница 17: ...er to the equipment Fuse Socket The fuse holders two fuses are embedded in the equipment Equipotential Terminal The equipotential terminal can be connected to the external equipotential line to preven...

Страница 18: ...her and then the holder for hand electrode 5 Lift up the back of the lower part of the equipment gently to remove the support pads at the back 6 Before taking out the equipment tighten up the screws c...

Страница 19: ...fuse socket and then plug in the power to the power socket 12 Put a spare fuse in a small plastic bag and attach it to the back of the equipment with tape When the fuse is brown you can replace it wi...

Страница 20: ...humidity 30 80 Air pressure 500hPa 1060hPa B Transporting before installation Before installation the equipment is in a packaging box provided by Biospace Use a carrier to move the box over or have t...

Страница 21: ...oadcell pad on top of the support pad I 7 Stick the head pad at the both corners Fold up the upper part of the equipment and put it in the box 8 Insert hinge pad into the box and tape the accessory ba...

Страница 22: ...urement 2 Exterior and Function of Keypad 3 Power Connection Getting Started 4 Initial Screen and Input 5 Personal Profile 6 Proper Posture 7 How to Operate the Equipment 8 Results Chapter 2 Managemen...

Страница 23: ...ore measurement If the subject already ate something please wait for 2 hours for digestion 3 Do not take a bath or shower before measurement Perspiring sweating results in a temporary change in body c...

Страница 24: ...enter the gender of the patient Enter Button This button is used to tell the system that data input is complete or move on to the next section B Function Button 5 buttons SETUP This button is used to...

Страница 25: ...r the scale adjusts the internal circuits and determines whether the peripherals listed in the setup are still in use The results of this initialization process will be displayed on the monitor Do not...

Страница 26: ...4 When the system boots up the initial screen comes up allowing the user to enter data into the system...

Страница 27: ...he patient and the user along the test by providing detailed and specific information C Analysis Result Window Before a results sheet is printed out the analysis result window displays the key figures...

Страница 28: ...5 C Height permissible range of input 95cm 220cm 3ft 1 4in 7ft 2 6in Use numeric buttons to enter height Heights can have one digit under the decimal point As the height the patient remembers might no...

Страница 29: ...rror occurs and press the backspace key to delete the existing data and re enter data An error occurs in the Initial screen after data entry is completed Use the direction button to move to the text f...

Страница 30: ...3 If the patient s hands are a bit too small for hand electrode pull the hand towards the thumb electrode so that the thumb can touch the button Do not press the button with the fingernails fingernail...

Страница 31: ...t tissues in the market It is strongly recommended to use the electrolyte tissues specifically designed for InBody720 C Body Posture During testing the LCD monitors display information on body composi...

Страница 32: ...et as close to the pure weight as possible take off a heavy winter coat or wristwatch before testing 3 Both heel and the ball of your feet should touch the foot electrode Step on the stand in barefoot...

Страница 33: ...or step on the foot electrode properly or if the patient s palms or soles are dry or have too much dead and hard skin the testing process may not initiate on its own In this case wipe up the patient s...

Страница 34: ...windows 9 The patient should place the hand electrode back to where it was and step down from the stand Do not drop the hand electrode as it contains electronic parts inside 10 Soon after the patient...

Страница 35: ...esity Diagnosis Edema Nutritional Evaluation Weight Management Body Balance Body Strength Weight Control BMR Fitness score 2 Various comprehensive evaluation The analysis result window of InBody720 su...

Страница 36: ...s to 25pin parallel port IEEE1284 or USB1 1 port InBody720 can use any printer that supports PCL3 interface or higher version For details on printer refer to the Chapter 5 Consumables As for the insta...

Страница 37: ...ody Water Protein Mineral and Body Fat Your own data are displayed here Total body weight is the sum of Body Fat and Fat Free Mass FFM FFM is the sum of Mineral and Soft Lean Mass SLM SLM is the sum o...

Страница 38: ...values Especially because body fat is more various among people than muscle mass each bar has different scale The value next to bar shows you the measured values and the end of bar indicates your pos...

Страница 39: ...evidence report June 1998 xiv Determination 2 Asian Pacific Standard BMI kg m2 Classification Risk of associated disease 18 5 Underweight Low high risk of other clinical disease 18 5 22 9 Normal Aver...

Страница 40: ...xt to the above bar represents the absolute value for lean body mass of an examinee in kilograms In the range 100 actually determines the length of the graph It represents ideal lean body mass in the...

Страница 41: ...tal edema score as well as total edema score 8 Visceral Fat Area VFA Visceral Fat Area is the cross sectional visceral fat area obtained from the CT Computed Tomography view of the abdominal region No...

Страница 42: ...data provided by InBody720 Target Weight kg It is the result of the calculation of the amount of the optimal muscle mass It is also based on the consideration of the other body components that the con...

Страница 43: ...lic Rate kcal Basal Metabolic Rate BMR is the minimal energy requirement for sustaining vital functions at rest With InBody720 BMR is estimated by a known regression equation based on FFM FFM is known...

Страница 44: ...1 Setup Menu 2 Quick Setup 3 DATABASE 4 Modification Example Chapter 3 Setup Establishment...

Страница 45: ...ub category has a list of further sub categories Previously selected items will be displayed Use the direction button to move to the category you want to select and modify using the direction buttons...

Страница 46: ...unit ethnic background and language Set Date Set the current date Set Time Set the current time in the order of OO hour OO min OO sec Display Mode Select the date display mode yy is for year mm is fo...

Страница 47: ...measurement duration is approximately 1minute which is relatively short Reactance value is not printed out Research Purpose The measurement duration is approximately 2 minutes Reactance value is prin...

Страница 48: ...When you use the network which uses DHCP server get instructions from a system administrator If you modified network setting please turn off and on the InBody720 again Lookin Body PC Ethernet Enable t...

Страница 49: ...until the next change 2 Items Race selection Select the race of the patient Weight adjustment You can adjust the measured weight If the clothes or jewelry the patient is wearing during the testing sig...

Страница 50: ...archives and the additional number of patients that can be entered in the archive are displayed To move through the archive windows use the direction keys To print out the test result of a particular...

Страница 51: ...ill pop up Press Enter button to quit setup The analysis results will be printed out on the A4 paper Use the standard A4 paper only 2 When using the printed result sheet Press the SETUP button Move to...

Страница 52: ...1 Error Messages 2 Trouble Shooting 3 Frequently Asked Questions FAQs 4 Customer Service Information Chapter 4 Problems and Solutions...

Страница 53: ...the object from the base frame and restart the equipment Enter personal data correctly This message appears when the value for age or height of the patients is out of the permissible range for these...

Страница 54: ...r bar Step 2 Check if the power comes on to the power bar and an electrical outlet the power bar is connected to Cause 3 Fuse blows Step 3 Check to see if the fuse in a fuse holder is functioning If n...

Страница 55: ...rinter displaying a message reporting paper jam Step 3 Check to see if paper is jammed in the printer Cause 4 A wrong printer is selected in the printer settings or the number of results sheet to be p...

Страница 56: ...is out of the permissible range of measurements and might see the accuracy of body composition analysis drop Testing is difficult with the children who cannot hold on to the hand or foot electrode du...

Страница 57: ...e a test Stand up for 5 minutes before tests Do not sit down and stand up right before a test Do not have a test while taking diuretic Avoid having a test during period Enter the exact height Keep the...

Страница 58: ...pace biospace co kr Biospace Inc 8820 Wilshire Blvd Suite 310 Beverly Hills CA 90211 U S A TEL 1 310 358 0360 FAX 1 310 358 0370 Homepage http www biospaceamerica com E mail USA biospaceamerica com Bi...

Страница 59: ...1 Consumables 2 Basic Equipment 3 Options Chapter 5 Consumables...

Страница 60: ...disinfecting effect B Results sheet Results Sheet size A4 210mmX297mm Number of Sheets 500sheets 1box Printed Condition 4colors Manufacturer for Biospace Co Ltd C Fuse Fuse holder is located inside t...

Страница 61: ...ility Chipset HP compatible Deskjet 920C 5550 3820 Only the printers that have one of the chipsets listed in the above table or support PCL3 or higher are compatible with the InBody720 Use the printer...

Страница 62: ...sultation to your clients System requirements for installation are Lookin Body 2 0 Lookin Body 3 0 Operating system Microsoft Windows 2000 XP compatible Windows2000 XP or Compatiable CPU IBM PC compat...

Страница 63: ...1 More About InBody720 2 Classifications 3 Specification 4 Worldwide Patents LIMITED WARRANTIES Appendix...

Страница 64: ...ormula as shown below V According to this expression if we know the L and the impedance value we get the volume That is to say if we know the height of the human body acting as a conductor and know th...

Страница 65: ...lular water minimizing the probability of errors caused by individual variations in the distribution of the body water or changes of it over the period The InBody720 can be reliably used on the patien...

Страница 66: ...kg Arm Muscle Circumference cm BMI kg m2 VFA Visceral Fat Area cm2 BMR Basal Metabolic Rate kcal Weight Control kg Target Weight Weight Control Fat Control Muscle Control Fitness Score Segmental Impe...

Страница 67: ...Area Growth Chart for the children under 18 of age Nutritional Evaluation Protein Mineral Fat Body Balance Body Strength Health Diagnosis Target Weight Weight Control Fat Control Muscle Control Fitne...

Страница 68: ...position based on bioelectrical impedance analysis and method thereof Registration number U S 6 256 532B1 The United States of America 2002 03 Apparatus and method for analyzing body composition based...

Страница 69: ...ect in material or workmanship 4 Thefollowingdefectsormalfunctionswillnotbecoveredundertheoneyearwarranty Any defect caused by user s fault Any defect or damage caused by not following the instruction...

Страница 70: ...50 60 Display Type 640 480 Color TFT LCD External Interface RS 232C 3EA USB Host Transferring database to external device 2EA Ethernet 10 100 Base T 1EA Printer Interface IEEE1284 25pin parallel with...

Страница 71: ......

Страница 72: ...InBody the product of great technology Experience its speciality...

Страница 73: ...analysis leading the health care market with the top quality body composition analyzers that have set the standard for diagnosis of obesity and health care Biospace focuses on product development and...

Страница 74: ...nBody has higher precision level for patients with special body figure so it helps doctors to provide more appropriate judgment and treatment to those Rehabilitation Orthopedic Pain clinic By providin...

Страница 75: ...can check body balance and development level by segment InBody provides information essential to check the effect of rehabilitation treatment or establish a direction for exercise Segmental Edema InBo...

Страница 76: ...www biospace co kr...

Страница 77: ...ison it does not effect the measurement Height needs to be inputted accurately as it will effect the measurement 6 Arms need to be away from the side of the body Not touching body Age Range 6 years to...

Страница 78: ...er protein mineral and body fat mass Weight Total Body Water Protein Mass Mineral Mass Body Fat Mass Muscle Fat Analysis The Muscle Fat Analysis consists of a comparison of weight skeletal muscle mass...

Страница 79: ...dy Fat Mass is within the standard range An examinee of this type will also exhibit a C shape However this person should be identified as having a weak body and not as being obese People who belong to...

Страница 80: ...Fat Percent Body Fat indicates the percentage of body fat to body weight Percent Body Fat Body Fat Mass Body Weight 100 The standard range of Percent Body Fat for males is 10 20 and 18 28 for females...

Страница 81: ...for the left leg at actual weight but closer to 115 at their ideal weight Visceral Fat Visceral fat is the fat potentially stored around your abdominal organs and a high visceral fat over a long peri...

Страница 82: ...ocess secondary to disease or poor nutrition BMC Bone Mineral Content Screening tool to monitor bone mineral Linked to Osteoporosis especially relevant to women reaching the menopause Weight bearing e...