Operation Manual BioSmart PV-WM v.029.1|03.2021|en
Page 13 of 24
BioSmart PV-WM Reader
Operation Manual
2.3.4
Installation Procedure
1)
If the operating conditions require the installation of a protective visor for the BioSmart PV-WM
reader, install the visor. For instructions on how to mount the sun visor, refer to the operating
instructions for the visor.
2)
On the reader, unscrew the screws holding the mounting plate and remove the plate from the back
cover.
3)
Mark the attachment points of the reader by placing the mounting plate on the surface. The
dimensions of the mounting plate are shown in Figure 5.
Figure 5
–
Mounting plate dimensions
4)
If the installation is carried out without using a protective visor, then drill holes in the marking points
and install the dowels from the fastening kit. If a protective visor for the BioSmart PV-WM reader is
used, then it already has holes for fastening using the bolts included in the BioSmart PV-WM visor kit.
5)
Carry out the cables routing in accordance with the recommendations stated in paragraph 2.3.22.3.2.
The cable must fit freely in the dedicated space on the mounting plate (see Figure 6).
65 ± 0,2
68 ± 0,2
86 ± 0,2
147 ± 0,2