Operation Manual BioSmart PV-WM v.029.1|03.2021|en
Page 12 of 24
BioSmart PV-WM Reader
Operation Manual
2.
Scope and sequence of the device external inspection
After receiving the reader, make an external examination of the product to check the integrity of the
packaging, no damage.
Open the product packaging, remove the reader and perform the reader initial inspection to check
damage.
Check the correspondence of the serial number of the reader to the number in the passport. The
reader serial number may be seen on the labels.
Check the completeness of the reader for compliance with the passport.
The Product Installation
2.3.1
Choosing the Reader Location
When choosing a place to install the reader, consider the following:
1)
The reader is recommended to be installed only on a vertical surface at a height of 150-170 cm from
the floor, based on the convenience of positioning the palm on the reader and presenting the card.
2)
The place of the reader installation should be chosen so that the light of direct sunlight or light from
other bright light sources doesn’t fall on the scanner surface. Otherwise, due to the illumination of
the optical scanner screen, the number of identification errors will significantly increase.
3)
To minimize the mutual negative influence of the built-in RFID-
card readers, it’
s not recommended
to install the reader at a distance of less than 80 cm from other RFID-readers and other sources of
electromagnetic interference.
4)
When installing the reader on a metal surface, the reading range of the RFID-card may decrease.
5)
If the in
stallation site is outdoors, it’
s additionally necessary to ensure:
the presence of a canopy or a special visor over the reader, which prevents the influence of
atmospheric precipitation and other liquids on the reader;
taking measures to preserve the dust and moisture protection of the reader (see paragraph
2.3.2
Guidelines for Cable Routing
Observe the following guidelines when routing cables:
1)
The cables routing must be carried out in compliance with the operation rules of electrical
installations;
2)
Don
’
t rout cables less than 30 cm away from sources of electromagnetic interference;
3)
The intersection of all cables with power cables is allowed only at right angles;
4)
Any cable extensions should only be made by soldering.
5)
Leave a margin of length for the cables connected to the reader, sufficient to lead the reader away
from the wall and access the jumpers.
6)
To connect the reader, use the types of cables shown in Table 5.
2.3.3
Actions Immediately Before Connection
Before connecting cables, check:
1)
Absence of mechanical damage on the palm vein reader scanner surface, printed circuit board and
the device case;
2)
The stripped ends of the cable for connecting the reader shouldn
’
t exceed 5 mm to avoid short
circuits.