BIOS Defender 500 Series Скачать руководство пользователя страница 12

20

21

Shipping 

When shipping your Defender, be sure to follow some simple 
guidelines to avoid costly damage to your property.  

•   Use adequate packing material. Whenever possible, use the 

original packing that came with your Defender. Or use a Bios 
Pelican carrying case, which provides a hard case shell for 
protection of your valuable equipment. If you do not already 
have a Bios Pelican case, visit us at www.biosint.com for  
more information on obtaining one.

•   Use a major freight carrier (e.g., FedEx, UPS) that supplies 

tracking numbers.

•   Insure your Defender. Bios is not responsible for damage  

occurred during transit.

•   Understand our mutual shipping obligations.  Bios is  

responsible for shipping cost only if the issue is product  
related and the Defender is still under warranty.

Tips and guidelines for sending your Defender to Bios

If you are sending your Defender for repair or evaluation (rather 
than elective Recertification), contact Bios for technical support 
or troubleshooting assistance prior to shipping the unit. Pro- 
vide us a detailed description of your issues.  If we are unable  
to resolve the situation by phone or email, we will issue you  
an RMA (return merchandise authorization) number. Follow  
online instruction for proper return procedure.

You can obtain an RMA number through our automated  
web-based system at http://www.biosint.com/contactUs/ 
rmaform.aspx.  RMAs also can be obtained through email  
to service

@

biosint.com, or by telephone at 973.492.8400.  

Our web site address is www.biosint.com.

Note: Bios will not evaluate or service your instrument without 
an RMA number.

If we find the issues you have identified are application related 
and not product related, an evaluation fee will be charged.

5.0

5.0 Shipping

Содержание Defender 500 Series

Страница 1: ...Defender 500 Series User Manual Driving a Higher Standard in Flow Measurement SM...

Страница 2: ...ftware 3 1 SKC CalChek Interface 3 2 Defender Firmware Upgrades 3 3 Annual Maintenance and Calibration 4 0 Shipping 5 0 Storage 6 0 Defender Specifications 7 0 Default Settings 8 0 Limited Warranty 9...

Страница 3: ...you have questions regarding its opera tion please contact Bios through our web site www biosint com or call us at 973 492 8400 to speak with a member of our professional customer service staff Your D...

Страница 4: ...pressure devices 2 1 Battery Charging installing and monitoring your Defender battery Your Defender battery is charged at the factory but we recommend that you make sure it is fully charged before in...

Страница 5: ...The Defender provides a menu of operational settings and com mands The four directional arrow buttons on the control panel allow you to navigate through the menu and select the desired settings for y...

Страница 6: ...If you wish to incorporate a time delay between consecutive measurements set Time Between from 1 to 60 minutes Units Measure gas Flow in cubic centimeters milliliters liters or cubic feet all units a...

Страница 7: ...SKC CalCheck Interface Magnification In the Defender 520 model this controls the amount of data on the display Select Zoom to view only flow measurements in larger font or select Detail to simultaneo...

Страница 8: ...Bios supplied leak test cap Leave the other port uncapped Press Enter on the control panel while the unit is still inverted Return the unit upright The leak test will progress If Defender leak test i...

Страница 9: ...er port Use inch diameter tubing Connect to outlet at top suction fitting when a device draws air such as sampler Connect to inlet at bottom pressure fitting when a device pushes air Do not cap the un...

Страница 10: ...terface for use with Bios Optimizer Software or with the SKC CalCheck Interface Visit www biosint com to find more information about Optimizer software and for access to available Optimizer or Defende...

Страница 11: ...ined to extremely close tolerances Various environ mental factors product wear drift of sensors or inadvertent damage may adversely affect your Defender s measurement accuracy or general performance F...

Страница 12: ...er warranty Tips and guidelines for sending your Defender to Bios If you are sending your Defender for repair or evaluation rather than elective Recertification contact Bios for technical support or t...

Страница 13: ...storage 6 0 7 0 7 0 Defender Specifications Technical data about your Defender Models 510L 520L from 5 500 mL min 510M 520M from 50 5 000 mL min 510H 520H from 300 30 000 mL min Measurements Volumetri...

Страница 14: ...e PC and RS 232 serial connection Bios Optimizer installation CD supplied no restrictions apply RS 232 cable supplied for Defender 500 Series data port to PC RS 232 serial port connection PC Card opti...

Страница 15: ...ration shall have no liability to repair or replace any Bios International Corporation product 1 That has been damaged following sale including but not limited to damage resulting from improper electr...

Страница 16: ...der for pressure sources or to the suction port for ver ifying suction pumps The unused port should be at atmospheric pressure with any cap or plug removed If you are calibrating a gas that requires a...

Страница 17: ...of the cell after a measurement this could be caused by A discharged battery not providing enough power to operate the internal valve properly Try charging the Defender Bright light shining into the...

Страница 18: ......

Страница 19: ...Measurement SM Bios International Corporation 10 Park Place Butler NJ USA 07405 Phone 973 492 8400 Toll Free 800 663 4977 Fax 973 492 8270 Email sales biosint com web www biosint com 2009 Bios Intern...

Отзывы: