background image

1. Introduction

Thank you for purchasing the BIOS Diagnostics

 Advanced Blood Pressure Monitor with Blood Pressure 

Analyzer Software. Designed for convenient and easy operation, this device provides a simple, yet accurate 
method to measure your blood pressure.

Your blood pressure is an important parameter that can be used to monitor your health. This device enables you 
to monitor your blood pressure regularly, and maintain a record of your blood pressure measurements. You can 
then use this record to assist your physician in diagnosing and maintaining a healthy blood pressure level.

1.1 Features

The BD850 is a fully automatic, digital, blood pressure measuring device with a unique fuzzy logic technology 
as well as patented MAM and PAD technologies. It can store up to 99 blood pressure readings for each of the 
two users.

It provides a fast and reliable measurement of systolic and diastolic blood pressure as well as heart rate using 
the oscillometric measurement method. 

MAM - Averaging Mode 

technology used in the device provides accurate measurements. Using three 

consecutive measurements, your result is calculated and displayed as a single averaged measurement 
on the display screen.

PAD - Pulse Arrythmia Detector

 technology displays pulse irregularities detected during a blood 

pressure reading. However, if the PAD symbol         appears on a regular basis (e.g. several times a 
week with measurement taken daily), we advise you to consult your doctor.  

• 

Hypertension Classification Indicator

 displays the range between which your blood pressure values lie.

• 

Blood Pressure Analyzer Software

 allows you to download, record and chart your readings to 

accurately monitor your daily readings. 

This device is easy to use and has been proven in clinical studies to provide excellent accuracy. Before using the 
BD850, read this instruction manual carefully and keep it in a safe place.

1.2 Important Information

Refer to the following sections to learn about important safety instructions and how to take care of the 
BIOS Diagnostics

 Advanced Blood Pressure Monitor with Blood Pressure Analyzer Software. 

1.2A Safety Information

•  Self-measurement means control, not diagnosis or treatment. Your values must always be discussed with 

your doctor or a physician who is familiar with your family history.

•  If you are undergoing medical treatment and receiving medication, consult your doctor to determine the 

most appropriate time to measure your blood pressure. Never alter the dosages of any medication without 
direction from your doctor.

•  Your blood pressure depends on several factors, such as age, gender, weight, and physical condition. It 

also depends on the environment and your state of mind at the time of measurement. In general, your 
blood pressure is lower when you are asleep and higher when you are active. Your blood pressure may be 
higher when recorded at a hospital or a clinic and may be lower when measured in the relaxing comfort of 
your home. Due to these variations, we recommend that you record your blood pressure regularly at home 
as well as at your doctor’s clinic.

Содержание BD850

Страница 1: ...ADVANCED BLOOD PRESSURE MONITOR INSTRUCTION MANUAL BHS A A BHS Protocol Recommended by the Canadian Hypertension Society Recommand par la Soci t canadienne d hypertension WITH COMPUTER LINK TECHNOLOG...

Страница 2: ...e Right Cuff 2 5 Storing the Cuff 3 Using the Device 3 1 Setting the Time Date and User 3 2 Enabling the MAM optional 3 3 Obtaining Accurate Measurements 3 3A Before Measuring 3 3B Common Sources of E...

Страница 3: ...6 Error Messages Malfunctions 7 Care and Maintenance 8 Lifetime Guarantee 9 Reference to Standards 10 Technical Specifications 11 Contact for Support...

Страница 4: ...sult your doctor Hypertension Classification Indicator displays the range between which your blood pressure values lie Blood Pressure Analyzer Software allows you to download record and chart your rea...

Страница 5: ...r is full Blood pressure is lower than normal after consuming alcohol after taking a bath The pulse display is not suitable for checking the frequency of heart pacemakers If you have been diagnosed wi...

Страница 6: ...s A deficient supply of blood to important organs heart brain muscles can be the result Furthermore with long term increased blood pressure values the heart will become structurally damaged There are...

Страница 7: ...ble that you are suffering from so called labile hypertension In any case please discuss the values with your doctor Correctly measured diastolic blood pressure values above 120mmHg require immediate...

Страница 8: ...of your normal blood pressure It is important to take regular daily measurements and to keep records over a period of time This information can be used to assist your physician in diagnosing and prev...

Страница 9: ...ay be applied The following illustration provides a flow chart of the MAM Sequence 2 Getting Started 2 1 About the BD850 This section describes the various components of the BD850 Measurement 1 Measur...

Страница 10: ...artment Insert the four AA batteries here 9 Upper Arm Cuffs Standard cuff for arm circumference 22 32 cm Large cuff for arm circumference 32 42 cm Fits into compartment on unit 2 2 About the LCD Scree...

Страница 11: ...e the standard size cuff If arm circumference measures 32 42 cm 12 6 16 5 use the large size cuff 2 5 Storing the Cuff The cuff used for measuring blood pressure is a delicate component of the device...

Страница 12: ...ess the button for over 3 seconds the user icon starts flashing Press the button to switch between user 1 and user 2 Press to confirm 2 You will see the MAM logo flashing along with the words OFF Pres...

Страница 13: ...ularly at the same time of day since blood pressure changes during the course of the day The ideal time to measure your blood pressure is in the morning after you wake up before breakfast and physical...

Страница 14: ...on the cuff must lie exactly over the artery which runs down the inner side of the arm d Tighten the cuff by pulling the end and closing the cuff e There should be little free space between the arm a...

Страница 15: ...ssing the button to preserve the batteries If no button is pressed for 3 minutes the instrument switches the display off 3 5 MAM Measuring Your Blood Pressure Using the MAM Feature When the unit is se...

Страница 16: ...ed range The classification is based on standards adopted from WHO World Health Organization which is recognized by the Canadian Hypertension Society CHS Refer to the chart below for details of the cl...

Страница 17: ...t you have your arm at the heart level Err 2 Unnatural pressure impulses influence the measurement result Reason The arm was moved during the measurement Avoid unnecessary movement or talking Err 3 Th...

Страница 18: ...ability Blood pressure values measured differ from those measured by the doctor Record the daily developement of the values and consult your doctor Note Individuals visiting their doctor fre quently e...

Страница 19: ...r be necessary return the unit with all component pieces Enclose proof of purchase and 5 00 for return shipping and insurance Ship the unit prepaid and insured at owners option to Thermor Ltd Repair D...

Страница 20: ...maximum Operation temperature 10 to 40 C Humidity 15 to 90 relative humidity maximum Display LCD Display Liquid Crystal Display Measuring method Oscillometric Pressure sensor Capacitive Measuring rang...

Страница 21: ...11 Contact for Support Thermor Ltd 16975 Leslie Street Newmarket ON L3Y 9A1 www biosexactly com Toll Free Help Line 1 866 536 2289 Email thermor thermor ins com Made in China TH1012_BD850 022210...

Отзывы: