Project Type
Instructions
Date: March 27 2020
Customer: Thermor Ltd
Job Number: TH1011
Item Number: 3AL1-3E
Designer: Alex Vranjesevic
Revision: B
Artwork is not to be amended or scaled. If any changes
are required please send through Thermor office with
instructions, and we will amend here and resend artwork
through. PLEASE RETURN WITH SIGNATURE
Contact: Graphic’s Department
Colour Breakdown
Reason For Project:
New Item:
New Branding: X
Design Update:
N/A:
UPC (For Reference Only)
i)
h)
f) You can adjust the level of your arm by putting a cushion under your arm.
Ideally the cuff should be at heart level.
g) Remain seated in a comfortable room temperature for at least 5
minutes, then start the measurement.
h) For those who cannot put the cuff on the left arm, put it on the right arm
as shown.
i) Consecutive measurements will cause blood accumulation in the lower
arm which will affect the measuring results. To improve reading
accuracy, raise the arm being measured, squeeze and relax your
hand several times, then take another measurement. Another
option is to take the cuff off and wait at least 5 minutes before
repeating measurement.
j) If this device was stored in low temperature, it is necessary to
leave it in room temperature for at least 1 hour, otherwise the
measurement can be inaccurate.
Comment:
Continue to use the same arm for comparisons. It is not unusual for there to be a difference in blood pressure
between arms.
Comparable blood pressure measurements always require the same conditions (Relax for several minutes before
taking a measurement).
ATTENTION: Do not use a cuff other than the original cuff contained in this kit!
3.4 Measuring Your Blood Pressure
After following the guidelines described in the previous section and placing the cuff around your upper arm, you are
now ready to measure your blood pressure.
Follow these steps to record your measurement.
1. Press the button to turn on the device and start measurement. The LCD screen is
turned on. The cuff begins to inflate while the increasing cuff pressure is displayed on
the screen. After the suitable inflation pressure is reached, the cuff stops inflating and
the pressure gradually falls. A long beep sounds when the measurement is completed.
The systolic and diastolic blood pressure values along with the pulse rate are displayed
on the screen. The measurement is displayed for approximately 3 minutes.
2. Switch off the device by pressing the button to preserve the batteries. If no button
is pressed for 3 minutes, the instrument switches the display off.
f)