Please read the instructions carefully before use.
The ear thermometer is a device capable of achieving infrared temperature measurement when placed in
the auditory canal of a patient. It is a safe means of measuring human body temperature through the ear.
SPECIFICATION:
The standard we adopted in EN12470-5:2003 Clinical thermometers - Part 5: Performance of infrared ear
thermometers (with maximum device).
This device complies with the requirements of IEC 60601-1:1998, and IEC 60601-1-2:2001.
Range of displayed temperature:
93.2°F to 111.2°F
(34.0°C to 44.0°C)
Display L°C (L°F) when the temperature is under 93.2°F (34.0°C)
Display H°F (H°C) when the temperature is over 111.2°F (44.0°C)
Operating ambient:
Temperature:
60.8°F to 95.0°F (16°C to 35°C)
Humidity:
≤
80%RH
Storage and transport condition:
Temperature:
-13°F to 131°F (-25°C to 55°C)
Humidity:
≤
85%RH
Display resolution temperature range:
0.1°F (0.1°C)
Accuracy:
±0.4°F (from 95.9°F to 107.6°F)
±0.2°C (from 35.5°C to 42.0°C)
Display:
liquid crystal display, 3 1/2 digits
Temperature value:
display the maximum temperature in measuring process
Temperature unit:
celsius of fahrenheit
Display of memory:
last ten memories
Low voltage warning:
the LCD display
and then a beep sound is heard
Power consumption:
9 million watt in measurement mode
Battery:
one 3V Lithium battery (CR 2032)
Battery life:
4000 measurements
Dimension:
110mm by 35mm by 35mm
Net weight:
Approx. 37g
Self-testing sequence:
Press the
‘ON/RECALL
’ button to turn on the thermometer and all of the symbols (See
Fig A) should be displayed on the LCD in one second.
CAUTION:
• Never use the thermometer for purposes other than those for which it is intended. Please follow the
general safety precautions when using on children.
• Never immerse the BIOS Diagnostics™ Instant Ear Thermometer into water or other liquids (not
waterproof). For cleaning and disinfecting please follow the instructions in the ‘Cleaning and storage’
section.
• Keep the thermometer away from direct exposure to the sun and keep it in a dust-free, dry area between
-4°F to 122°F (-20°C to 50°C).
• Do not use the thermometer if there are any signs of damage on the measuring tip or the instrument itself.
If damaged, do not attempt to repair the instrument.
• This BIOS Diagnostics™ Instant Ear Thermometer consists of high quality precision parts. Do not drop this
instrument. Protect it from severe impact and shock.
WARNING
• Use of this BIOS Diagnostics™ Instant Ear Thermometer is not intended as a substitute for consultation
with your physician.
Instant Ear Thermometer
127DU