b. Contact your dealer for proper wiring information.
c. Shut off the main breaker to the spa, wait for 30
seconds before resetting.
9.)
Refer to No or Low Bromine residual. (See page 10)
The cell seems to be noisy....
1.)
It is normal to be a bit noisy during the cleaning cycle.
If it is constant or persistent, the cell may need to be
replaced.
2.)
Check diagnostics
"t"
to ensure motor current is between
0.4 to 0.7 Amps.
TROUBLESHOOTING
CONDITIONS (cont'd)
No or Low Bromine Residual.....
1.)
Ensure that the Bromine test has been performed properly.
a. Test strips require a 1 second dip to read the pH and
Alkalinity levels, and then a second dip for 30 second to
read the Bromine level.
b. Liquid Test Kits (OTO, DPD) require a certain amount
of drops into their measuring vial.
c. It is possible that DPD may become bleached out if the
bromine level is extremely high.
2.)
Check the Diagnostics
"t"
.
a. Press both buttons (
SET LEVEL
&
BLAST
) simultaneously
until a
"t"
is seen in the display window and immediately
release buttons. You will see:
"Pc" (Motor Current) should be 0.4 to 0.7
"Cc" (Cell Current) should be 0.9 to 3.0
"Cu" (Cell Voltage) should be 13.0 to 17.0
This cycle will continue for 2 times.
3.)
What is the Maintenance Level set at?