problem.
b. Green: Low Bromine (may also be extremely high
bromine)
2.)
Has 58 grams sodium bromide and 454 grams non-iodized
table salt (sodium chloride) been added for every 378.5
litres (83.3 imp gal) of water in your spa?
3.)
Have the two (58 grams) bags of potassium monopersulphate
been added to the spa?
4.)
When you look at the BiO2 touch pad, what do you see?
a.
A,C,F,J,P,=,
or
/
/
are fault codes. Consult the Fault Code
Guide for further instruction.
5.)
What is the Bromine Level?
a. The bromine level should be between 3 and 5 ppm.
b. Press the
BLAST
button if the bromine level is below
2.
6.)
Check the diagnostics
"t"
.
a. Press both buttons (
SET LEVEL
&
BLAST
) simultaneously
until a
"t"
is seen in the display window and immediately
release the buttons. The following sequence will appear:
"Pc (Motor Current) 0.4 to 0.7
"Cc (Cell Current) 0.9 to 3.0
"Cu (Cell Voltage) 13.0 to 17.0
This cycle will repeat 2 times.
b. If the current and voltages are half of what they
should be, and you have a 240 VAC BiO2 unit (201-XX-XX),
check the input power, it may be wired for 120 VAC
instead of 240 VAC.
7.)
Is the BiO2 touch pad functioning when the spa jets are
in operation?
a. If not, it is possible that BiO2 is not wired for 24
hours continuous power.