background image

11-APR-1997

BIO2

Domestic Spa Bromine Generator

READ THE LABEL AND OPERATOR

=

S MANUAL BEFORE USING

Over Bromination (greater than 10 PPM) may cause

corrosion to some spa components.

Check the spa water bromine level on a regular basis

(weekly) to ensure the bromine level is between 3-5 PPM.

Heavy use of the spa (excessive contamination) may

require longer recovery times. (A return to minimum of
3 ppm bromine). Recovery time may be reduced by adding

a shock compound to the water.

CERTIFIED TO COMPLY WITH THE LIMITS FOR A

CLASS B COMPUTING DEVICE PURSUANT TO

SUBPART J OF PART 15 OF THE FCC RULES.

MODEL 101-PS-C

INPUT: 120 VAC .7 Amps, 60 Hz

OUTPUT: 20 VDC 3.5 Amps

EPA Est. NO. 69439-NV-001 (US)

REG. NO. 24694

PEST CONTROL PRODUCTS ACT

PATENT No. 5,545,310 OTHER PATENTS PENDING

BioQuest

4750 Longley Lane #202

Reno. NV 89502

CUSTOMER HELP DESK 1-800-516-4028

BIO2

Domestic Spa Bromine Generator

READ THE LABEL AND OPERATOR

=

S MANUAL BEFORE USING

Содержание BIO2 101-PS-C

Страница 1: ...s A return to minimum of 3 ppm bromine Recovery time may be reduced by adding a shock compound to the water CERTIFIED TO COMPLY WITH THE LIMITS FOR A CLASS B COMPUTING DEVICE PURSUANT TO SUBPART J OF...

Страница 2: ...CE PURSUANT TO SUBPART J OF PART 15 OF THE FCC RULES MODEL 201 PS C INPUT 240 VAC 3 Amps 50 60 Hz OUTPUT 20 VDC 3 5 Amps EPA Est NO 69439 NV 001 US REG NO 24694 PEST CONTROL PRODUCTS ACT PATENT No 5 5...

Страница 3: ...there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turnin...

Страница 4: ...t without the prior written consent of BioQuest Inc Disclaimer BioQuest Inc has reviewed this manual thoroughly in order that it be an easy guide to your BiO2 sanitizing system All statements technica...

Страница 5: ...generates the powerful sanitizing agents oxygen and bromine The water with sanitizers re enters the spa from the cell at about 3 7 litres per minute through the wall fitting Power supply This unit con...

Страница 6: ...tact dealer or BiO2 Help Desk 1 800 516 4028 Please refer to page 8 of this manual OPERATING BiO2 With this basic understanding of the BiO2 Components and their function let s discuss how to operate t...

Страница 7: ...ge recommended by NSPI National Spa and Pool Institute for safe water During the BLAST cycle a rotating bar will appear on the LED display and the CELL ON LED will be lit The BLAST cycle may be deacti...

Страница 8: ...BiO2 has to work 2 The amount of use your spa will get The more the spa is used the greater the number of contaminants enter the water and the harder BiO2 has to work If your spa use is occasional or...

Страница 9: ...ense mode for 2 hours after spa use and then will return to the Maintenance Mode If your BiO2 system is not equipped with Usage Sense simply push the BLAST button as you enter the spa This effectively...

Страница 10: ...ter in your area is hard high levels of calcium BiO2 may deposit some white flakes on the floor of the spa This is normal BiO2 is actually removing hardness from the spa water This process can continu...

Страница 11: ...taneously Keep both buttons pressed until a t appears see illustration below then release the buttons A sequence of letters and numbers will be displayed one digit at a time that will indicate how the...

Страница 12: ...n 3 and 5 ppm b Press the BLAST button if the bromine level is below 2 6 Check the diagnostics t a Press both buttons SET LEVEL BLAST simultaneously until a t is seen in the display window and immedia...

Страница 13: ...has been performed properly a Test strips require a 1 second dip to read the pH and Alkalinity levels and then a second dip for 30 second to read the Bromine level b Liquid Test Kits OTO DPD require...

Страница 14: ...Is the spa filter clean 7 If BiO2 unit is equipped with Usage Sense press the BLAST button for a boost in the sanitizer level I can t adjust the display 1 Lockout function may be enabled a To disable...

Страница 15: ...uring the cleaning cycle comes on for every 3 hours of operating time scale may be deposited into the spa water Stain and scale inhibitor may be used The Check Salt Light is on 1 If it is steady a The...

Страница 16: ...refill with fresh water d Recheck the sodium chloride level TROUBLESHOOTING FAULT CODES Flashing service light FAULT CODE DESCRIPTION RECOMMENDATIONS J Low Cell Current 1 Check Cu Cell Voltage and Cc...

Страница 17: ...e Cell a Use a garden hose to fill the cell at the wall fitting discharge outlet to push air out of the cell Let water run at medium pressure for 30 seconds b Press BLAST If A AC reappears call for se...

Страница 18: ...l Let water run at medium pressure for 30 seconds 2 Cell wire disconnected a Check all wire connections to ensure that all are tightly connected 4 hour limit for Usage Sense 1 Denoted by two horizonta...

Страница 19: ...BioQuest help desk for further assistance This label transcript service is offered by the Pest Management Regulatory Agency to provide efficient searching for label information This service and this i...