BIOPAC Systems B-ALERT X10 Скачать руководство пользователя страница 6

 

 

 

D.

 

Minimum

  

System

 

Requirements

 

 

 

Personal

 

computer

 

(PC)

 

with

 

minimum

 

Pentium

TM

 

2.4

 

GHz

 

processor;

    

 

Minimum

 

of

 

1

 

GB

 

of

 

installed

 

RAM

 

memory

 

and

 

4

 

MB

 

virtual

 

memory;

 

 

Windows

 

XP

 

or

 

Windows

 

7

 

operating

 

system;

 

 

.NET

 

framework

 

version

 

3.5

 

installed;

 

 

Minimum

 

of

 

50

 

MB

 

hard

 

disk

 

space

 

per

 

5

hour

 

session;

  

 

One

 

CD

ROM

 

drive;

 

 

VGA

 

or

 

higher

 

resolution

 

video

 

adapter;

 

 

One

 

available

 

USB

 

port.

 

 

 

Monitor

 

size

 

between

 

15”

 

and

 

21”

 

required

 

for

 

Baseline

 

acquisition.

 

 
 

BIOPAC Systems, Inc.

 

 

B-Alert X10 User Manual

 

|       

6

 

 

Содержание B-ALERT X10

Страница 1: ...User Manual 42 Aero Camino Goleta CA 93117 805 685 0066 http www biopac com Distributed by BIOPAC Systems Inc Manufactured by Advanced Brain Monitoring Inc...

Страница 2: ...n 9 C Application 11 D Additional ECG Placements 14 E Ready to Collect 14 F Post session Clean up 15 A Common Headset and Sensor Issues 17 Chapter 4 Specifications 19 A B Alert X10 19 B Environmental...

Страница 3: ...ons The Sensor Headset collects physiological signals from the sensors placed on the user sampling at 256 Hz The headset performs analog to digital conversion encoding formatting and transmitting of a...

Страница 4: ...ation are required B ALERT X10 has no alarms classifications such as drowsiness There are only alarms for indications of excessive artifact Do not use the B ALERT X10 as a substitute for clinical ECG...

Страница 5: ...on the EEG sensors as this will cause permanent damage and void the Warranty This device has been tested and found to comply with the limits for medical devices to the IEC 60601 standards These standa...

Страница 6: ...MB virtual memory Windows XP or Windows 7 operating system NET framework version 3 5 installed Minimum of 50 MB hard disk space per 5 hour session One CD ROM drive VGA or higher resolution video adap...

Страница 7: ...oam Sensors 12cc Syringe ECG Leads left Mastoid right Disposable Electrodes Synapse Gel Bottle Tube Cleaning Tools Tweezers Electrode Brush ABM USB Host device B Alert Dongle left Optional ESU MC righ...

Страница 8: ...inimum 8hrs It takes 2 3hrs to fully charge a headset To recharge the Headset follow the steps below 1 Verify the Headset is in the off position Insert the X10 cable adapter into the sensor headset 2...

Страница 9: ...rough each side of the Sensor Headset strap holders and fasten the Velcro Do this equally to both sides but leave loose for easy application to subject later c Verify that the Mastoid Leads are plugge...

Страница 10: ...the foam and dispense gel You should see the gel begin filling the center of the foam ii The gel can also be dispensed into the foam from the sides by pushing the tip into either side of the foam unti...

Страница 11: ...a snug fit c d Verify that the Neoprene Strap is centered on the subject and that it is not resting on the ears e While holding the strip in front of the subject with the foam pieces facing away from...

Страница 12: ...subject s head while maintaining the correct alignment on the scalp g h h i Verify that all sensor sites are contacting the head and adjust straps if necessary j j Gently plug connector on the back o...

Страница 13: ...4 Mastoids and ECG Leads BIOPAC Systems Inc B Alert X10 User Manual 13...

Страница 14: ...thing or muscles which can compromise signal integrity Contact BIOPAC for additional information on alternative ECG placement E Ready to Collect 1 Plug in the USB Host Device B Alert Dongle or ESU to...

Страница 15: ...the number of obstructions and avoid metal objects in the line of sight of the head and host units F Post session Clean up 1 Removal of Sensor Headset and Electrodes BIOPAC Systems Inc B Alert X10 Use...

Страница 16: ...timal recordings clean the strip immediately after use Do not reuse foam sensors Strips are recommended for 25 30 uses Do not aggressively scrub the Sensor pads when cleaning If Sensor pad is removed...

Страница 17: ...ensor Issues The following topics describe critical troubleshooting methods to undertake when encountering problems during the setup session of a subject Hands should be away from Face Part thick hair...

Страница 18: ...Systems Inc B Alert X10 User Manual 18 NOTE The recommendations are not necessarily listed in a logical sequence Use best judgment to determine which trouble shooting tips are most relevant to the pro...

Страница 19: ...either EEG or EOG Resolution 16 bit Bandpass Characteristics 0 1 Hz and 65 Hz at 3dB attenuation obtained digitally with Sigma Delta A D converter Noise 3 2 mV peak to peak out to 100 Kohms resistance...

Страница 20: ...ration Transportation Storage Temperature 5o C to 40o C 41o F to 104o F 20o C to 70o C 4o F to 140o F 20o C to 70o C 4o F to 140o F Altitude 390 m to 3012 m 1254 ft to 9 882 ft 390m to 3012 m 1254 ft...

Страница 21: ...he dealer or an experienced radio TV technician for help This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful int...

Страница 22: ...determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol...

Страница 23: ...nsmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separation distance for the higher frequenc...

Страница 24: ...out regard or effect given to its or any other jurisdiction s conflicts of law jurisprudence D Product Limited Warranty The B Alert X10 Sensor Headset product is warranted to be free from defects in m...

Страница 25: ...r any damage resulting from service work performed by the customer or its representative All returns to Biopac Systems Inc must include a Return Merchandise Authorization RMA obtained by calling Custo...

Отзывы: