BIOPAC Systems B-ALERT X10 Скачать руководство пользователя страница 3

 

Chapter

 

1:

  

Introduction

 

and

 

Safety

 

Information

  

 

A.

 

About

 

the

 

B

ALERT

 

X10

 

 
         

The

 

B

ALERT

 

X10

 

is

 

an

 

internally

 

battery

 

powered

 

FDA

classified

 

Type

 

BF

 

device

 

intended

 

for

 

continuous

 

use

 

(7

9

 

hours).

  

The

 

B

ALERT

 

X10

 

provides

 

an

 

integrated

 

approach

 

for

 

wireless

 

acquisition

 

and

 

recording

 

of

 

electroencephalographic

 

(EEG),

 

electrooculographic

 

(EOG)

 

and

 

electrocardiographic

 

(ECG)

 

signals.

   

The

 

system

 

utilizes

 

the

 

patented

 

B

Alert

 

Sensor

 

Headset

 

and

 

EEG

 

sensors,

 

which

 

record

 

high

 

quality

 

EEG

 

that

 

can

 

be

 

obtained

 

in

 

five

minutes

 

of

 

set

up

 

time

 

with

 

no

 

scalp

 

preparation.

   

The

 

wireless

 

technology

 

allows

 

the

 

user

 

to

 

be

 

untethered

 

and

 

move

 

around

 

the

 

clinic

 

(or

 

in

 

the

 

field)

 

while

 

real

 

time

 

data

 

is

 

collected,

 

displayed,

 

and

 

analyzed.

  

 

The

 

B

ALERT

 

X10

 

acquires

 

nine

 

channels

 

of

 

monopolar

 

EEG

 

recordings

 

with

 

a

 

linked

 

mastoid

 

reference.

  

The

 

10

th

 

channel

 

is

 

a

 

programmable

 

gain

 

option

 

that

 

can

 

be

 

used

 

for

 

EOG

 

or

 

ECG.

  

The

 

B

ALERT

 

X10

 

consists

 

of:

  

Head

 

and

 

Host

 

Units

 

for

 

bi

directional

 

transmission

 

of

 

digitized

 

physiological

 

signals,

 

a

 

Neoprene

 

Strap,

 

and

 

a

 

Sensor

 

Strip

 

with

 

EEG

 

sensor

 

sites

 

in

 

the

 

frontal

 

(Fz,

 

F3

 

and

 

F4),

 

central

 

(Cz,

 

C3

 

and

 

C4)

 

and

 

parietal

occipital

 

(POz,

 

P3,

 

and

 

P4)

 

regions.

   

 

The

 

Sensor

 

Headset

 

collects

 

physiological

 

signals

 

from

 

the

 

sensors

 

placed

 

on

 

the

 

user

 

sampling

 

at

 

256

 

Hz.

 

The

 

headset

 

performs

 

analog

to

digital

 

conversion,

 

encoding,

 

formatting

 

and

 

transmitting

 

of

 

all

 

signals.

   

The

 

signals

 

communicate

 

using

 

a

 

2.4

 

to

 

2.48

 

GHz

 

radio

 

transmitter.

  

B

Alert

 

Acquisition

 

utilizes

 

the

 

bi

directional

 

capabilities

 

of

 

the

 

system

 

to

 

initiate

 

scalp

electrode

 

impedance

 

monitoring,

 

and

 

monitors

 

the

 

battery

 

capacity

 

in

 

the

 

Head

 

Unit.

  

A

 

custom

 

USB

 

Host

 

Device

 

(B

Alert

 

Dongle

 

or

 

ESU

MC)

 

is

 

used

 

as

 

the

 

base

 

unit

 

affixed

 

to

 

the

 

PC

 

workstation.

 

 

B

Alert

 

Acquisition

 

software

 

consists

 

of

 

several

 

modules

 

that

 

allow

 

the

 

user

 

to

 

acquire,

 

store,

 

view,

 

and

 

analyze

 

physiological

 

signals

 

acquired

 

by

 

the

 

wireless

 

system.

   

The

 

software

 

provides

 

a

 

simple

 

graphical

 

interface

 

for

 

establishing

 

and

 

controlling

 

data

 

acquisition.

  

Patented

 

algorithms

 

can

 

be

 

selected

 

to

 

monitor

 

artifacts

 

that

 

impact

 

signal

 

quality

 

in

 

real

 

time,

 

and

 

provide

 

users

 

feedback

 

when

 

thresholds

 

(for

 

artifact)

 

are

 

exceeded.

 

EEG

 

Power

 

Spectral

 

Densities,

 

EEG

 

classifications,

 

and

 

Heart

 

rate

 

measures

 

can

 

be

 

generated

 

in

 

real

time

 

or

 

off

line.

 

 
 

B.

 

Intended

 

Use

 

 
 

The

 

B

Alert

 

X10

 

system

 

is

 

intended

 

for

 

use

 

in

 

clinical

 

and

 

research

 

settings,

 

by

 

trained

 

technicians,

 

to

 

measure

 

and

 

record

 

the

 

electrical

 

activity

 

originating

 

from

 

the

 

brain

 

(EEG),

 

the

 

BIOPAC Systems, Inc.

 

 

B-Alert X10 User Manual

 

|       

3

 

 

Содержание B-ALERT X10

Страница 1: ...User Manual 42 Aero Camino Goleta CA 93117 805 685 0066 http www biopac com Distributed by BIOPAC Systems Inc Manufactured by Advanced Brain Monitoring Inc...

Страница 2: ...n 9 C Application 11 D Additional ECG Placements 14 E Ready to Collect 14 F Post session Clean up 15 A Common Headset and Sensor Issues 17 Chapter 4 Specifications 19 A B Alert X10 19 B Environmental...

Страница 3: ...ons The Sensor Headset collects physiological signals from the sensors placed on the user sampling at 256 Hz The headset performs analog to digital conversion encoding formatting and transmitting of a...

Страница 4: ...ation are required B ALERT X10 has no alarms classifications such as drowsiness There are only alarms for indications of excessive artifact Do not use the B ALERT X10 as a substitute for clinical ECG...

Страница 5: ...on the EEG sensors as this will cause permanent damage and void the Warranty This device has been tested and found to comply with the limits for medical devices to the IEC 60601 standards These standa...

Страница 6: ...MB virtual memory Windows XP or Windows 7 operating system NET framework version 3 5 installed Minimum of 50 MB hard disk space per 5 hour session One CD ROM drive VGA or higher resolution video adap...

Страница 7: ...oam Sensors 12cc Syringe ECG Leads left Mastoid right Disposable Electrodes Synapse Gel Bottle Tube Cleaning Tools Tweezers Electrode Brush ABM USB Host device B Alert Dongle left Optional ESU MC righ...

Страница 8: ...inimum 8hrs It takes 2 3hrs to fully charge a headset To recharge the Headset follow the steps below 1 Verify the Headset is in the off position Insert the X10 cable adapter into the sensor headset 2...

Страница 9: ...rough each side of the Sensor Headset strap holders and fasten the Velcro Do this equally to both sides but leave loose for easy application to subject later c Verify that the Mastoid Leads are plugge...

Страница 10: ...the foam and dispense gel You should see the gel begin filling the center of the foam ii The gel can also be dispensed into the foam from the sides by pushing the tip into either side of the foam unti...

Страница 11: ...a snug fit c d Verify that the Neoprene Strap is centered on the subject and that it is not resting on the ears e While holding the strip in front of the subject with the foam pieces facing away from...

Страница 12: ...subject s head while maintaining the correct alignment on the scalp g h h i Verify that all sensor sites are contacting the head and adjust straps if necessary j j Gently plug connector on the back o...

Страница 13: ...4 Mastoids and ECG Leads BIOPAC Systems Inc B Alert X10 User Manual 13...

Страница 14: ...thing or muscles which can compromise signal integrity Contact BIOPAC for additional information on alternative ECG placement E Ready to Collect 1 Plug in the USB Host Device B Alert Dongle or ESU to...

Страница 15: ...the number of obstructions and avoid metal objects in the line of sight of the head and host units F Post session Clean up 1 Removal of Sensor Headset and Electrodes BIOPAC Systems Inc B Alert X10 Use...

Страница 16: ...timal recordings clean the strip immediately after use Do not reuse foam sensors Strips are recommended for 25 30 uses Do not aggressively scrub the Sensor pads when cleaning If Sensor pad is removed...

Страница 17: ...ensor Issues The following topics describe critical troubleshooting methods to undertake when encountering problems during the setup session of a subject Hands should be away from Face Part thick hair...

Страница 18: ...Systems Inc B Alert X10 User Manual 18 NOTE The recommendations are not necessarily listed in a logical sequence Use best judgment to determine which trouble shooting tips are most relevant to the pro...

Страница 19: ...either EEG or EOG Resolution 16 bit Bandpass Characteristics 0 1 Hz and 65 Hz at 3dB attenuation obtained digitally with Sigma Delta A D converter Noise 3 2 mV peak to peak out to 100 Kohms resistance...

Страница 20: ...ration Transportation Storage Temperature 5o C to 40o C 41o F to 104o F 20o C to 70o C 4o F to 140o F 20o C to 70o C 4o F to 140o F Altitude 390 m to 3012 m 1254 ft to 9 882 ft 390m to 3012 m 1254 ft...

Страница 21: ...he dealer or an experienced radio TV technician for help This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful int...

Страница 22: ...determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol...

Страница 23: ...nsmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separation distance for the higher frequenc...

Страница 24: ...out regard or effect given to its or any other jurisdiction s conflicts of law jurisprudence D Product Limited Warranty The B Alert X10 Sensor Headset product is warranted to be free from defects in m...

Страница 25: ...r any damage resulting from service work performed by the customer or its representative All returns to Biopac Systems Inc must include a Return Merchandise Authorization RMA obtained by calling Custo...

Отзывы: