background image

PLEASE READ AND SAVE THESE

IMPORTANT INSTRUCTIONS.
With proper care and use, this Bionaire™

air purifier will give you fresh, clean air

for many years.

NOTE:

Before reading these instructions, please

view the corresponding illustrations.

DESCRIPTIONS 

(SEE FIG 1/4)

A. Inlet Grill
B. Washable Foam Pre-Filter
C.HEPA/Carbon Filter
D.Filtered Air Outlet
E. Filter Indicator Light
F. Reset Button
G.Ionizer Light
H.Ionizer Control
I. Speed Control
J. Power Light

SAFETY PRECAUTION

Carefully read and retain all instructions before
using the air purifier.
• To avoid fire or shock hazard, check that the

voltage on the product corresponds to your
electricity supply and plug directly into an
electrical outlet.

• To avoid fire hazard, never put the cord under

rugs, or near any heat source.

• Carefully discard any plastic wrapping that was

used for the packaging.

• Do not use the air purifier outside.
• Do not place the unit near any heat source or

in direct sunlight.

• Always unplug the air purifier before removing

the grill, changing the filters, cleaning the air
purifier or whenever it is not in use.

• Do not use in or around water or any other liquids.

Do not attempt to wash the unit under running
water.

• Use appliance only for intended household use

as described in this manual.

• Ensure that all air openings are not restricted

or covered in any way.

• Do not place anything on top of the unit.
• Never insert any object into any openings.
• Do not use the air purifier if any part is missing

or damaged in any way.

• Do not attempt to repair or adjust any mechanical

functions of this unit. If the unit becomes damaged
return to the place of purchase or phone the
helpline number on the back of this leaflet.

• If the supply cord or plug is damaged, it must

be replaced by the manufacturer or its service
agent or a similarly qualified person in order to
avoid hazard.

• The air purifier contains no user serviceable

parts and should the product suffer damage or
breakdown it must be returned to the manufacturer
or its service agent.

• Should the air purifier stop working, first check

the fuse in the plug (UK only) or fuse/circuit breaker
at the distribution board is operating, before
contacting the manufacturer or service agent.

HOW THE AIR PURIFIER WORKS

Dirty, dust laden air is drawn through the back of
the air purifier and through the multi-stage filtration
system.
1. The carbon filter will help clear odours making

the air cleaner and fresher.

2. The HEPA filter entraps 99% of all smaller visible

and non-visible particles down to 2 microns in
size.   

PRODUCT FEATURES
Filter Life Indicator

Your air purifier has an indicator light that illuminates
when its time to change the filters.

Ioniser

Your Bionaire™ Air Purifier has an independently
controlled ioniser, which when turned on, releases
negative ions into the outgoing filtered air. Ions
are tiny particles that carry either a positive or
negative charge. These ions exist naturally all
around us in the air,  water and ground. Both positive
and negative ions are colourless, odourless and
completely harmless.
Negative ions help the air purification process by
attaching themselves to very small airborne particles
in the room. These particles take on a negative
charge and may join with positively charged particles,
such as dust, pollen, smoke and pet dander to form
larger particles that are then more readily captured
by the filter system, or they may be attracted to
positively charged surfaces like walls or floors.
You may also note, after extended use, that dust
may have collected around the grills or front panel.

This is from the ionisation effect caused by the
negative ions exiting from the air outlet.This dust
does not come from the air output, but is drawn
out of the uncleaned air going past the air outlet.
This is additional evidence of the air cleaning
effectiveness of negative ions. The dust can be
easily removed with a clean, dampened cloth or
soft brush.

NOTE:

it is important to change the HEPA filter

at recommended intervals. Using the ioniser in
conjunction with dirty filters may result in dirty

U.K. and IRELAND

particles exiting the air purifier and being attracted
to walls, carpets, furniture and other household
objects. These dirty particles may prove very difficult
to remove.   

PRE-OPERATING INSTRUCTIONS

1. After removing the unit from the box, remove

the plastic covering from the unit.

2. Select a firm level place where there are no

obstructions to the air inlet (front grill) or filtered
air outlet.

3. Remove the inlet grill by pulling the grill towards

you.

4. Remove both HEPA filters by gripping on both

sides and pulling forward.

5. Remove protective plastic bag from each filter

cartridge. The filter clip can only be attached
to the hang tabs on the filter one way (see fig 3).
The filter clip should easily slide onto the filter
hang tabs. Do not use force whilst attaching
the filter clip to the filter. Align the clip on the
HEPA filter with the rails on the inside of the unit.

NOTE:

The pleated material and rubber gasket

should be facing towards the unit when applied.

6. Replace the inlet grill by sliding back on to the

unit. Make sure that it snaps securely into position
(the grill only goes on one way).

NOTE:

Do not point outlet towards wall.   

OPERATING INSTRUCTIONS

1. Plug into a suitable 220 – 240V electrical outlet.
2. Select the required operating Speed: Hi (     ),

Medium (     ), Low (     ) by sliding the switch
to the appropriate setting.

3. To release negative ions into the filtered air

slide the Ioniser button (       ) to ON. The amber
light will illuminate.

4. The ioniser will not work unless the unit is running.
5. For optimum air filtration, it is recommended to

operate the air purifier continuously. Its rugged
motor is designed to give many years of service.

6. For continuous use it is recommended to operate

the air purifier at the Medium (    ) setting. For
quieter operation or use in a bedroom, select
the Low (     ) setting. When high levels of air
pollution are present, select the HI (     ) setting
to quickly circulate clean filtered air. 

CLEANING AND MAINTENANCE

1. Turn the air purifier off and unplug it before cleaning.
2. The outside of the air purifier can be cleaned

with a soft, clean dampened cloth. 

3. The filtered air outlet can be cleaned of dust

with a small, soft brush.

4. If you wish to clean the inside of the air purifier,

please only use a dry, soft cloth to wipe it down.

FILTER REPLACEMENT 

IMPORTANT:

IN ORDER TO RETAIN THE

EFFICIENCY OF YOUR AIR PURIFIER, THE
HEPA FILTER NEEDS TO BE CHANGED EVERY
6 MONTHS.
1. Every few weeks check the condition of the

pre-filter.

2. Remove the inlet grill. If the foam pre-filter has

collected a noticeable amount of dust, remove
it from the inlet of the grill and wash it in warm
soapy water. Rinse and dry the pre-filter thoroughly
before replacing it in the inlet of the grill.

3. With the inlet grill removed, remove the HEPA

cartridge and dispose in the dustbin. DO NOT
try to wash and re-use the HEPA filter. Replace
with a new HEPA filter-BAPF30 removing the
protective plastic bag before inserting into the
air purifier.

4. Align the clips on the side of your HEPA filter with

the rails on the inside of the unit. Gently slide
the filter onto the rails.

5. The filter clip should easily slide onto the filter

hang tabs. Do not use force while attaching the
filter clip to the filter. Align the clip on the side of
your HEPA filter with the rails on the inside of
the unit.

NOTE:

The pleated material and rubber gasket

should be facing towards the unit when applied.

6. Replace the inlet grill by sliding back on to the

unit. Make sure that it snaps securely into position
(the grill only goes on one way) 

NOTE:

Do not point outlet towards wall. 

7. After replacing the HEPA filters, RESET the

Filter Life Indicator by inserting a small object
(such as a pin or paper clip) into the hole marked
RESET (      ).    

REPLACEMENT FILTERS
BAPF30 HEPA Filter (usage 2 pcs)

The Holmes Group reserves the right to change
or modify any specifications without notice.

2

3

BAP422IUK04EM1 Visual.qxd  3/12/04  3:12 AM  Page 7