LiFePO4 chemistry is an evolution in rechargeable battery technology. It is safer, non-toxic, 
 higher performing, and longer lasting compared to lead-acid batteries. Bioenno Power  
provides the highest quality LiFePO4 battery from our ISO9001 certified production facility  
that guarantees maximum performance. Please carefully review the information below as 
 they are vital to the safety and performance of the battery.  

 

 

Typical Applications 

 

 

 

Solar energy storage

 

 

Electric motor 

 

 

Backup power supply (UPS)

 

 

Ham radio

 

 

Portable electronic equipment power (audio, visual, networking, power tools etc.)

 

 

Drop in replacement for sealed lead acid battery (SLA)

 

 

 

 

Contents 

 

 

 

     1 -   Bioenno Power BLF-12200AS LiFePO4 Battery  
     1 -   User Manual  
     1 -   Compatible Charger with 20A output  

 

 

Specifications 

(summary)

 

 

Dimensions    

 

19.6 in. x 6.8 in. x 9.6 in. (496 mm x 172  
mm x 242 mm)  

Weight 

 

53.5 lbs.  (24.3 kg.)  

Battery nominal voltage and capacity 

 

12V, 200Ah  

Charging Voltage 

 

14.6V  

Charging Current 

 

20A  

Open Circuit Voltage Range 

 

14.6VDC  

Maximum Peak Pulse Current 

200A (5sec) 

Maximum Continuous Discharge Current 

 

100A  

Operating Temperature 

 

- 10°C to 60°C  

Protection: 

PCM/BMS

 

 

Overcharge, overdischarge, overcurrent, 
temperature, balancing  

Terminal / connector type 

 

Screw Terminal

  

For the full specification, please visit www.bioennopower.com 

 

 

 

Caution 

 

●  Do not disassemble.

 

 

●  Do not short circuit positive and negative terminals.

 

 

●  Use only LiFePO4 compatible chargers. Do not use Lead Acid battery chargers.

 

 

●  Do not submerge in water, the seal on the battery is not intended to withstand water pressure

 

 

●  Do not throw in fire or dispose of improperly. Recycle the battery at a facility that accepts lithium 

battery

 

 

● 

BEFORE DISCHARGE CONFIRM TERMINAL SCREWS ARE WRENCH TIGHTENED TO ENSURE PROPER 
CONTACT IS MADE 

 

 

 

 

 

 

 

 

 

 

 

 

Last Revised 04/24/2019 

 

 

 

 

 

Instructions for Use 

 

 

 

Charging 

 

 

 

1. 

Only use 

14.6V, LiFePO4 compatible

 chargers to charge the battery. The charging current 

should not exceed 

20A

. If you need a charger, please contact us.  

2. 

Fully charge the battery 

before first use

.  This depends on the output of the charger but is 

typically about 6 hours.  

3. 

If your battery came with a Bioenno Power charger, there are two LED lights on the charger, 
LED 1 and 2. LED 1 should turn red whenever a load is connected or when the charger is 
plugged into the wall. During charging both LED 1 and 2 are red. When the battery is fully 
charged, LED 1 will be red and LED 2 will be green.  

4. 

LiFePO4 does not suffer “memory effect” so please keep the battery fully charged for daily 
use. Cell balancing only occurs when the battery is fully charged (top-end balancing).  

5. 

Do not

 charge the battery in temperatures below 0°C. This can cause damage to the cells.  

   

Discharging 

 

 

 

1. 

Make sure your load accepts 12V nominal voltage.  

2. 

Ensure the connection between the battery and the load can handle the current draw. Please 
consult references for the appropriate wire type.  

3. 

Maximum Continuous Draw is 

100A.  

Please make sure your electrical load consumes a 

current 

less than 100A continuous and 1200 watts of power

.    

4. 

The battery outputs a steady voltage around 12.8V until very little capacity remain, 

do NOT

 

rely on voltage as an indicator of remaining capacity.  

  

Series and Parallel Connection 

 

 

 

We do not recommend using our LiFePO4 batteries in series or parallel connection if a single battery 

of equivalent size can be used instead. The PCM/BMS built into each battery is intended only for 
operation with a single battery and we do not guarantee the operability of multiple batteries in series 
or parallel configuration. Please take the information below into consideration if you must use a 
series or parallel configuration.  

  

Series:   

Each battery must be charged separately

, all batteries should be fully charged before 

connecting in series.  

Parallel: 

Only connect batteries with equal state of charge in parallel. 

Also, measure the 

internal resistance of each battery and only use batteries with closely matched internal 
resistance. It is highly recommended that resistors be used to achieve equal internal 
resistance among multiple batteries. It is also highly recommended to add fuse(s) to the 
circuit for safety reasons.   

     

Please keep in mind a series or parallel connection can fail with a number of consequences, from 

early cut off to possibly a fire. Always exercise caution and observe closely at all times. The 
customer assumes all responsibility in the event of a series or parallel connection or connections.

 

 

 

 

  

Maintenance and Storage 

 

  

The battery requires no manual maintenance due to the included PCM/BMS. However, please 

follow the below guideline for best life cycle.  

1. 

Even though the LiFePO4 chemistry is relatively stable, protect the battery from shocks and 
drops to prevent internal short circuit.  

2. 

For long term storage, fully charge the battery and then discharge to 50% of the full capacity. 

Do NOT

 leave the battery unattended for more than 6 months.  

3. 

For the best life cycle, avoid using the battery in extreme temperatures and avoid highly 
variable pulsing loads.  

  