background image

G-Wave

7

Operating Instructions and Parts Manual

Surface Mounted High Speed Hand Dryer

Anti-theft bolt

Lock: Right
Unlock: Left

HEPA FIlter

If the LED light on the front of the unit fl ashes red then 
the HEPA fi lter needs to be changed. The HEPA fi lters last 
for 50,000 uses. 

To change the fi lter slide the anti theft lock to left and 
remove the fi lter case from the underside of the unit. 
Remove the old HEPA fi lter from the case and replace 
with a new one. 

When a new fi lter has been correctly installed the LED 
light will fl ash twice after fi ve secconds. If the light does 
not fl ash then the fi lter needs to be re-installed cor-
rectly.

Warning – if the fi lter is not replaced in time, it may 
interrupt air fl ow and overheat the motor. In this case, 
the warranty will be invalidated. 

The fi lter must be replaced every 3-6 months to avoid 
invalidating the warranty period.

Always use the unit with a genuine fi lter and the water 
tank in place.

Do not attempt to wash and re-use the HEPA fi lter. The 
fi lter works for 50,000 uses, after this it should be dis-
posed of and replaced by another fi lter.

Do not install the fi lter cartridge if the fi lter is wet or 
damp, it must be perfectly dry. If the cartridge is in-
stalled wet it can cause serious motor damage and the 
warranty will be invalidated.

Gel Blocks

The gel block is situated in the underside of the fi lter 
case. The gel block should be replaced every month, 
each pack contains 12 blocks.

Changing The Filter and Gel Block

Gel block

HEPA Filter

To order Gel Blocks and HEPA Filters please contact us:

call:

 01404 814292 

email:

 [email protected]

or visit:

 www.dripdropdry.com

Product

Order Code

Antibacterial HEPA fi lter

HDS-GW-HEPA-FILTER

Moisturising Gel

HDC-G-Wave GELS

Содержание G-Wave

Страница 1: ...1 G Wave Hand dryer Automatic High Speed...

Страница 2: ...tor when tank is full Filter Sensor LED indicator when filter needs to be replaced Air Purification Enzyme HEPA Filter H13 simple cartridge replacement system Air Freshener Organic moisturiser sanitiz...

Страница 3: ...the risk of fire electric shock and injury please observe the following Always use genuine spare parts Do not use for purposes other than drying hands Do not place foreign objects in the unit Do not c...

Страница 4: ...ode Antibacterial HEPA filter HDS GW HEPA FILTER Moisturising Gel HDC G Wave GELS Biodrier Anti Bacterial HEPA Filter The Anti Bacterial Filter is fitted to ensure dust and airborne bacteria is restri...

Страница 5: ...ull alert Flashing red light Filter change alert When a new filter has been installed correctly the LED light will flash twice after five secconds If the light does not flash then the filter needs to...

Страница 6: ...tions and Parts Manual Surface Mounted High Speed Hand Dryer If the LED light on the front of the unit flashes blue then the water tank needs to be emptied The water tank should be cleaned and emptied...

Страница 7: ...will be invalidated The filter must be replaced every 3 6 months to avoid invalidating the warranty period Always use the unit with a genuine filter and the water tank in place Do not attempt to wash...

Страница 8: ...G Wave 8 Operating Instructions and Parts Manual Automatic Surface Mounted High Speed Hand Dryer Diagram...

Страница 9: ...over 19 Back panel 20 Power cord closing cover 21 Wall bracket 22 Air valve cover 23 Valve inner 24 Filter sponge 25 Filter bracket 26 Switch A 27 Switch B 28 Heat sink Key Description 29 Main board 3...

Страница 10: ...rcuit breaker with the appropriate rating Circuit cable must fit current consumption for this unit This unit has been designed for indoor use only pro tected from water sun and extreme temperatures Do...

Страница 11: ...G Wave 11 Installation Template Operating Instructions and Parts Manual Automatic Surface Mounted High Speed Hand Dryer...

Страница 12: ...FW3 LTD Biodrier Unit 3 Woodlands Business Park Burlescombe Devon EX16 7LL tel 44 0 1823 672 970 email sales biodrier com...

Отзывы: