Executive
3
Operating Instructions and Parts Manual
Surface Mounted High Speed Hand Dryer
General Safety Information
This product is intended for installation by a
qualifi ed service person. Use AWAG No.16 solid
conductor for wiring.
Failure to properly ground unit could result in
electrical shock and/or death.
Disconnect power at the service breaker before
installing or servicing.
NOT FOR HOUSEHOLD USE - MAY CAUSE BURNS
“IMPROPRE A L’USAGE DOMESTIQUE - PUET
OCCASIONNER.”
WARNING
NOTE: Do not install dryer over wash basin.
Type Y attachment
If the power supply cord is damaged, it must be
replaced by the manufacturer or its service agent or a
similar qualifi ed person in order to avoid a hazard.
Means for disconnection must be incorporated in the
fi xed wiring in accordance with the wiring rules.
Installation
Installation must be carried out only by a qualifi ed
electrician
1. Make sure power supply breaker is switched off .
Installation must be carried out in accordance with the
current edition of the local wiring regulations code
having jurisdiction. Installation should be performed
only by a qualifi ed electrician.
2. Place template against wall at desired height
(see mounting height recommendations) and mark
locations of 4 mounting holes and wire service entry at
knockout (KO) location.
NOTE: For two or more dryers, dryers should be no
closer than 24 inches (610 mm) on centre.
3. Connect supply wires to terminal block where
indicated and connect ground wire to baseplate with
ground screw.
Connections:
A Type: Power cable not equipped
1. Secure the line and connect the power cable into the
proper terminal block locations. Verify connections are
correct before proceeding.
2. Cover the power connector with the provided
housing cover (Power Supply Cover Kit)
Minimum wire cross section: 2x1mm2
B Type: Power cable equipped