ALARM STATUSES
Service
NO
1. Clean the burner
2. Clean the chamber beneath the turbulators
1. Replace the igniter
2. Check output on electronics (relay) with
voltmeter
3. Check the fire probe (tCHB: 200~700 at burn)
Deactivate protection by pressing the button
Fill the container with pellets
Mandatory use of pellets up to 30mm!
YES
NO
Is the burner
clean?
Does the igniter
work?
YES
NO
Are there pellets in
the container?
NO
YES
Is STB protection
turned on?
ALARM FIRE
Unsuccessful ignition