Definition of Symbols 

 

The following symbols and their associated definitions are used and implied throughout this 
manual. 

 

 

Содержание 840-000,

Страница 1: ...BIODEX MULTI JOINT SYSTEM INSTALLATION INSTRUCTIONS 840 000 840 000 10 840 000 30 850 000 850 000 10 850 000 30 FN 08 051 CLR Rev A 9 19...

Страница 2: ...request or directly from the Biodex website http www biodex com If the desired information is not found please feel free to contact a local distributor or Biodex directly at supportservices biodex com...

Страница 3: ...mbols 4 1 Installation Instructions 6 Tools Required 6 Installation Procedure 6 Monitor Install Procedure 8 Cabling for CDS Power Receptacle 8 Seat Lift Power Connection 10 AC Input Receptacle Power C...

Страница 4: ...4 Definition of Symbols The following symbols and their associated definitions are used and implied throughout this manual...

Страница 5: ...ns System Power Requirements Provide 220 VAC 60 Hz 20 amp dedicated electrical service with dedicated ground Locate within ten feet of ear of the T base Receptacle will be a single Hubbell IG 5461 rat...

Страница 6: ...he chair on top of the chair T base Align the holes and use a 5 16 Allen wrench to tighten Be careful not to slide the chair around too much as this may cause the paint to scratch 13 Remove the dynamo...

Страница 7: ...7 Figure 1 1 Multi Joint System Cart and Monitor from the Rear...

Страница 8: ...cedure Figure 1 2 Rear View of the CDS Cart Cabling for CDS Power Receptacle Figure 1 3 Power Receptacles on the Back of Seat CDS Cart Power Receptacle Seat Lift Power Receptacle 195 to 245 Volt AC In...

Страница 9: ...e Screws from the CDS Cart Power Receptacle Figure 1 5 Loosen the Clamp on the Cable Figure 1 6 Cable Positioned at CDS Cart Power Receptacle 1 Strain Relief Slot Facing Up Cable Clamp Strain Relief S...

Страница 10: ...Cart Power Receptacle Seat Lift Power Connection Figure 1 8 Loosen the Cable Clamp Screw and Replace the Clamp on the Cable Figure 1 9 Seat Lift Receptacle 1 Seat Lift Receptacle 1 2 3 Strain Relief...

Страница 11: ...t Lift Power Cord AC Input Receptacle Power Connection Figure 1 11 Loosen the Clamp on the Cable Figure 1 12 Loosen the Cable Clamp Screw and Remove the Strain Relief Cable Clamp Screw Seat Lift Power...

Страница 12: ...12 Figure 1 13 Removing the Screws from the AC Input Receptacle Figure 1 14 Installing the AC Input Cable 3 3 1 2 Cable Clamp Screw...

Страница 13: ...STATE CONTACT AT SITE PHONE FAX Biodex Representative Installation Start Time Serial Number Model Number Software Version Firmware Version Biodex Contacts 1 800 224 6339 Software Support ext 2120 Tech...

Страница 14: ...pauses both on the dynamometer and hand held and rotate buttons on the dynamometer Comments 6 In the reactive eccentric mode check speeds and torque limits Comments 7 In the isokinetic mode check spee...

Страница 15: ...nctioning properly The Biodex representative has instructed the facility on startup hardware and software The facility is capable of proper operation of the Biodex System BIODEX REPRESENTATIVE DATE Si...