biodex 058-800 Скачать руководство пользователя страница 20

 

20

           

 

 

      

 

 

 

 

Optional 

056-463 

Grid, X-ray 

056-862 

Battery and Charging Unit, 115 VAC 

056-863 

Battery and Charging Unit, 230 VAC  

056-850 

IV Pole, Rail Mounted 

056-851 

Drain Bag Frame 

056-853 

Crutch, Knee, Simplicity (pair) 

058-860 

Drain Pan, Stainless Steel 

058-862 

Stirrups, PAL with Boot Pad (pair) 

058-863 

Arm Board, Dura Board with Pad (pair) 

058-865 

Arm Board, Standard (pair) 

058-866 

Cassette Tray, 11" 

×

 14" 

 

Replacement 

056-802 

Bellows Skirt, disposable plastic, 250/roll (Fits Urology & Brachytherapy 
C-Arm Tables 840, 800, 810, and 820) 

046-275 

Dispenser, Disposable Protective Roll 

 

 

 

 

 

 

 

 

 

 

 

   

 

Содержание 058-800

Страница 1: ...UROLOGY BRACHYTHERAPY C ARM TABLES INSTRUCTIONS FOR USE 058 800 058 805 058 810 058 815 FN 20 324 CLR 11 20...

Страница 2: ...equest or directly from the Biodex website www biodex com tables800 If the desired information is not found contact a local distributor or Biodex directly at supportservices biodex com Thank you Biode...

Страница 3: ...Made Easy 8 2 Operating Instructions 10 The Locking Brakes and Swivel Casters 10 Fowler Positioning 11 Using the Hand Held Controller 11 Using the Foot Controller 12 Disposable Skirt Optional 13 I V P...

Страница 4: ...4 Definition of Symbols The following symbols and their associated definitions are used and implied throughout this manual...

Страница 5: ...2012 or IEC 60601 1 2012 reprint ANSI AAMI ES60601 1 2005 A1 2012 C1 2009 A2 2010 CAN CSA C22 2 No 60601 1 14 CE Class I Non measuring FDA Class II Equipment IEC 60601 2 46 Edition 3 0 Type B Applied...

Страница 6: ...product are not permitted and will void the manufacturer s warranty Unauthorized modification of the product may result in a hazard to the user and or patient Do not modify this equipment without aut...

Страница 7: ...use in a client environment For product specifications refer to the Table of Contents This medical electrical equipment requires special precautions regarding EMC and must be assembled and placed into...

Страница 8: ...ides capability for vascular cardiac and other general C Arm applications Select from knee crutches or the PAL stirrups arm boards or drain systems Contraindications The Urology and Brachytherapy C Ar...

Страница 9: ...and Film Cassette Tray 7 Rail Mounted I V Pole 8 Head End Locking Brakes and Swivel Casters 9 Vertical Doors for adding transfer or radiolucent extension 10 Battery Pack 11 Arm Boards 12 Foot End Ind...

Страница 10: ...ces and across firm rugs The foot end casters are locked from either side of the table while the head end casters are locked together using the Caster Brake Locking Bar To lock the foot end brakes and...

Страница 11: ...owler Back must be set in one of the eight positions provided To lower the Fowler Back depress and hold the Fowler Back button on the underside of the Fowler Back grip and position the top as desired...

Страница 12: ...Y motion Releasing the rocker switch at any time immediately stops the motion NOTE When the table is used in a wet environment it is recommended that the Foot Controller be covered with a plastic bag...

Страница 13: ...xtension is used Stand at the foot end of the table and press the extension release levers located under the middle of each leg extension rail The extension can be slid out from the table Close the ve...

Страница 14: ...re the pole To adjust the height of the I V pole loosen the height adjustment locking knob and raise or lower the top section of the pole to the appropriate height Tighten the locking knob to secure K...

Страница 15: ...ob on the block move the arm board to the desired position and re tighten the knob Drain Bag Holder Optional A flexible drain bag holder is available for this table To install loosen the clamps on the...

Страница 16: ...f desired the pan can be stored in the table by simply pushing in on the drain pan support bars Figure 2 9 The Drain Pan Properly Installed X Ray Grid Optional The optional removable x ray grid is 103...

Страница 17: ...h mechanism To remove the cassette grasp the tray handle and lift it up 1 4 before sliding it toward the side of the table It is not necessary to remove the tray to remove the cassette There are holes...

Страница 18: ...s and dirt accumulation 3 Periodically inspect all welds 4 Periodically check bolts on table tighten if necessary 5 Periodically inspect all strap holders Any holder that feels loose should be removed...

Страница 19: ...rol activates all motions Foot Control activates all motions Fuses on Control Box F1 250V AC 16A Fast blow 6 3x32mm F2 250V AC 16A Fast blow 6 3x32mm F3 250V AC 2A Fast blow 6 3x32mm Optional X Ray Fi...

Страница 20: ...3 Crutch Knee Simplicity pair 058 860 Drain Pan Stainless Steel 058 862 Stirrups PAL with Boot Pad pair 058 863 Arm Board Dura Board with Pad pair 058 865 Arm Board Standard pair 058 866 Cassette Tray...