May 22, 2013

GRADIENT STATION

BIOCOMP Model 153 

Gradient forming software Version 5.3 

Fractionation software Version 8.03

OPERATOR’S MANUAL

SECTION 1.  INTRODUCTION

1.1   WARRANTY AND SERVICE

BioComp has a policy of complete customer satisfaction.  If, during the first thirty (30) days, you are 
unhappy with the GRADIENT STATION, you may return it for a full refund.

BioComp warrants this instrument to be free of defects in workmanship for a period of one year from 
the date of  receipt for all electronic and mechanical parts. Liability is limited to repairs or replacement 
of the unit at BioComp's discretion. This warranty is in lieu of all other warranties either express or 
implied.

Claims against this warranty must be made by first contacting BioComp 

 (phone (506) 454-6410)

.  At 

this time the remedy will be determined.  Units returned to BioComp without our knowledge and 
permission will not be accepted.

Claims for shortages or damage in transit must be reported to BioComp within ten (10) working days of 
the date of receipt.  Such claims made after this period cannot be honored.

1.2   MAINTENANCE

Other than the tightening of loose screws and the removal of spilled gradient solutions, no user service 
is required.  The instrument contains a computer which should not be tampered with.  In the unlikely 
event of computer failure, contact BioComp and we will ship you a new printed circuit board and 
simple instructions for its installation.

1.3   ELECTRICAL SURGE PROTECTION

As with any computer, voltage spikes and power surges can severely damage the sensitive chips in this 
instrument.  You are strongly encouraged to purchase a surge protector from your local computer or 
hardware store and plug the instrument into it.  Since surges and spikes can occur at any time, it is also 
wise to turn the unit off when not in use to reduce your instrument's exposure to them. 

1.4   GOODS DAMAGED IN TRANSIT

If the instrument or any of the accessories are damaged when you receive them, it is critical that you 
save the shipping carton(s) and contact us immediately.  We will inform you of the return procedure 
and shipping addresses to put on the box.  If the box is damaged to such an extent that returning the 
instrument in it would risk further damage, 

save the box

 for inspection by the shipper who will be 

4

Содержание GRADIENT STATION 153

Страница 1: ...ftware version 8 03 Gradient forming software version 5 3 OPERATOR S MANUAL 2013 BioComp Instruments Inc 650 Churchill Row Fredericton New Brunswick Canada E3B 1P6 Ph 800 561 4221 506 454 6410 Fx 506...

Страница 2: ...ient Station 7 3 2 Gradient Forming attachment 8 SECTION 4 ORDERING INFORMATION 4 1 The Gradient Station Base unit 8 4 2 Gradient Forming 8 4 2 1 Tube holders 8 4 3 Gradient Fractionation 8 4 3 1 Tube...

Страница 3: ...PART 2 GRADIENT MASTER MANUAL PART 3 GRADIENT FRACTIONATOR MANUAL PART 4 GRADIENT PROFILER MANUAL where applicable PART 5 GRADIENT RUN PARAMETERS last pages...

Страница 4: ...this period cannot be honored 1 2 MAINTENANCE Other than the tightening of loose screws and the removal of spilled gradient solutions no user service is required The instrument contains a computer whi...

Страница 5: ...r Coombs work with the purification of viruses led him to develop an exquisitely sensitive band visualization system T4 phage at 108 phage ml can be visualized with the naked eye Ribosomal subunits ar...

Страница 6: ...l tube length Number of Fractions 1 99 in each of 10 sections per gradient Band Illumination System 20W halogen spot with dichroic reflector Rinse Capability programmable in any order up to 9 events b...

Страница 7: ...SECTION 3 PARTS DIAGRAMS 3 1 THE GRADIENT STATION 7...

Страница 8: ...ailable for quick seal vertical rotor tubes but they cannot be fractionated with this device 4 3 Gradient Fractionation Includes the following accessories 1 Manual 1 Left wing for extended working are...

Страница 9: ...with dichroic reflector 151 905 check valve assembly for piston air rinse sample 151 905 11 check valve assembly for piston air rinse sample for 11 mm tip 151 931 Bag of 50 mist filter discs 151 919...

Страница 10: ...racks 5 3 Assemble the Gradient Forming attachment Carefully remove the Gradient Forming attachment from its box and attach it to the right wing position While supporting it screw in one of the same...

Страница 11: ...the top of the syringe barrel under the screw heads on either side of the notch in the right wing Fill the reservoir with FILTERED water or buffer depending on your needs Small particles of dust and...

Страница 12: ...d and two 6 pin sockets labelled tilt and rotate Insert the motor plugs onto their 6 pin sockets Note that the motor plugs have red stripes on one side The must face OUT away from the white plastic ba...

Страница 13: ...he computer to the bent edge of the front panel using 3 more 8 32 screws as shown 5 6 Install the power plug You are now ready to power up the unit Find the external power supply 12VDC Powergate trans...

Страница 14: ...ns that its smart key has been pressed The dedicated keys in the second row are used only for fractionation and have self explanatory labels AIR turns on the air pump forcing air into the collection t...

Страница 15: ...hown in A Adjust the feet under the corners of the instrument until the level is centered Next turn the level so it runs side to side as shown B Turn the knob clockwise or counter clockwise to level t...

Отзывы: