Bio Medic Data Systems DAS-8010 Скачать руководство пользователя страница 8

www.BMDS.com 1-800-526-BMDS or 302-628-4100 for Support Questions

SYSTEM SETUP

8

Setup instructions for both the DAS-8010 and DAS-8020 are exactly the same and extremely easy.

1.  Unpack and inventory system components. There should be the DAS-8010/8020 reader unit, 

a 12-volt power supply, an RSP smart probe, and a black RJ-11 coil cord for connecting the smart 

probe to the reader system. A disc with the BMDS Serial USB Driver is provided for installation on 

Windows XP through Windows 7 (Windows 10 provides native Serial USB support).   

 

In addition, if ordered, there could be a USB data cable, a 9-pin Serial data cable, a smart probe 

stand, and DASHost Utility Software. 

2.  Connect the unit to the 12-volt power supply. Plug the power supply to a standard outlet and 

test for function by turning on the power switch located on the front of the unit. Turn the unit off after 

confirmation.  The LED is 

RED

 for OFF and 

ORANGE

 for ON.   

 

NOTE: The power supply provided has a small BMDS sticker located on the bottom of the unit.  It 

has been calibrated to operate with all BMDS reader systems.  DO NOT use non-approved power 

supply units with your readers.  Doing so could create interference with transponder reads, failure of 

the sensitive smart probe or complete de-tuning of all equipment components. 

3.  Connect the RSP Smart Probe to the reader system. Using the supplied black coil cord, connect 

one end to the back of the reader and the other end to the smart probe. This is a specially configured 

6 pin RJ-11 cord provided by BMDS and not a standard phone or other similar in appearance cord. 

BMDS cords have a reverse connection and special power handling capabilities. Do not substitute 

coil cord for generic cord. 

4.  Connect the final data cable from the unit to a functioning respective port on your computer. 

The new DAS-8010 and DAS-8020 systems can now connect to your computer via three different 

port options. Two modern USB options (Serial USB or Keyboard HID USB) and a legacy 9-pin 

RS-232 serial connection. If connecting by either serial USB or RS-232, a BMDS driver will need 

installation for systems running Windows XP through Windows 7. Windows 10 has native driver 

support. Please contact BMDS for connections to Windows 8 and Windows 8.1. 

5.  Power on the system. Once all connections have been made, you can power on the complete 

system using the power switch.  In addition to the Power LED light, the probe LED and connection 

LED will light to indicate that the system is functioning correctly. 

6.  Start to collect data reading the specific transponders tuned to your specific smart probe 

reader.

NOTICE

The RSP-8004 is an IMI probe and can read only the IMI-500 and IMI-1000 

transponder. 

Содержание DAS-8010

Страница 1: ...Bio Medic Data Systems www BMDS com 1 800 526 BMDS or 302 628 4100 for Support Questions DAS 8010 20 WITH RSP 8004 User Manual English v 1...

Страница 2: ...roduced in whole or in part without the prior written consent of Bio Medic Data Systems Any permitted copies must include the same proprietary and copyright notices as were affixed to the original Und...

Страница 3: ...ional companion software Host DAS USB Data Cable www BMDS com 1 800 526 BMDS or 302 628 4100 for Support Questions DAS 8010 20 WITH RSP 8004 CHECK LIST DAS 8010 Unit RJ 11 Coil Cable RSP 8004 DC12V Po...

Страница 4: ...ystem Overview 7 System Setup 8 System Communication Options 9 Using DAS 8010 8020 with RSP 8004 10 RSP 8004 Keypad and Display 11 RSP 8004 Reading Micro Transponders 12 13 Connecting to DAS Host 8000...

Страница 5: ...data Data scanned will populate data fields in any active program window If the data collection software requires a dedicated secure connection use the Serial USB or RS 232 port for communication When...

Страница 6: ...Power Button www BMDS com 1 800 526 BMDS or 302 628 4100 for Support Questions DAS 8010 20 WITH RSP 8004 6 OLED Display Power Scan Button Reader Head Auto Scan Button Beep Button Power Button...

Страница 7: ...computer or data collection software To do this the reader unit is paired with a BMDS Smart Probe currently available probes are either the RSP 8004 for the IMI 500 and IMI 1000 read only transponders...

Страница 8: ...mplete de tuning of all equipment components 3 Connect the RSP Smart Probe to the reader system Using the supplied black coil cord connect one end to the back of the reader and the other end to the sm...

Страница 9: ...serial USB driver The connected computer will assign a unique COM port assignment for use with the data collection software BMDS Custom USB Serial drivers are provided for use with Microsoft Windows X...

Страница 10: ...be will energize the transponder which will in turn send data back to the system For optimal scanning the transponder should be separated from other transponders within the scanning area The transpond...

Страница 11: ...icate duplicate filtering While in this mode the probe will prevent accidental duplicate con secutive reading of the same transponder If the same transponder is scanned on the following scan a beep wi...

Страница 12: ...ata ports Do not read the Micro Transponder from the side or at right angles Once again the general rule is to have the length of the probe in line with the length of the transponder about 2 to 3 inch...

Страница 13: ...er in an applicator needle for scanning or mapping use the following technique Place the cap directly onto the bullseye of the probe You should get an instant read when the needle assembly touches the...

Страница 14: ...d turn reader on 2 Open the DASHost 8000 program on your desktop 3 If properly connected there should be a COM port selection in the drop down menu available in the Port Setup section If multiple COM...

Страница 15: ...www BMDS com 1 800 526 BMDS or 302 628 4100 for Support Questions CONNECTING TO DAS HOST 8000 15...

Страница 16: ...te Window are non functional with RSP 8004 and IMI Micro Transponders Scan Read button acts just like the SCAN keypad on the smart probe Auto Scan On can also be activated and is also similar to the A...

Страница 17: ...iage Return character ASCII 13 and a Line Feed character ASCII 10 TAB This will transmit a Tab character ASCII 9 COMMA This will transmit a comma character ASCII 44 CR This will transmit a Carriage Re...

Страница 18: ...D5E54080B Animal 10002 6D6F45053D Animal 10003 4C0730056C Animal 10004 6D5471787D Animal 10005 Mapping is activated on the smart probe by holding down and releasing the SCAN button The M LED will ligh...

Страница 19: ...pped code Once completed Select Save File and Exit to create a MAP file If a current existing MAP file is entered the file will be updated with the new entries Select Exit Only if the mapping session...

Страница 20: ...www BMDS com 1 800 526 BMDS or 302 628 4100 for Support Questions NOTES 20...

Страница 21: ...www BMDS com 1 800 526 BMDS or 302 628 4100 for Support Questions NOTES 21...

Страница 22: ...www BMDS com 1 800 526 BMDS or 302 628 4100 for Support Questions NOTES 22...

Страница 23: ...www BMDS com 1 800 526 BMDS or 302 628 4100 for Support Questions NOTES 23...

Страница 24: ...emperature Transponder IMI Implantible Micro Identifucation and the BMDS logo are trademarks of Bio Medic Data Systems Inc Covered by various U S and International patents and patents pending U S Pate...

Отзывы: