Bio-Doremi BDL-600 Скачать руководство пользователя страница 10

5) Main Operation

A. Master Registration

PWR

Press the PWR key to turn on the power

Press the SET(rear panel) to turn into setting 
Mode (

Shutter be remained open in setting mode

)

SET

Press the No.1 REG to register Master or User

1.REG

Press the No.1 MASTER REG to register Master 
User

1.MAST

Master

ID

Input selected master ID ( 4 digit )

Press the ENT to register ID

ENT

Place master fingerprint on the sensor two times
( Register two images : Place two fingerprints 

by turns or one fingerprint two times on sensor)

Master

Fingerprint

Press the ENT to back to main menu

ENT

Select other menu or press the Set key on the 
Internal case to finish all procedure

Main Menu

- 10 -

Содержание BDL-600

Страница 1: ...Bio Doremi Bio Doremi Dual Security Fingerprint Door Lock User s Manual BDL 700 BDL 730 BDL 600 POTECS CORPORATION...

Страница 2: ...egistration Deletion 10 B User Registration 11 C User Deletion 12 D All User Deletion 13 E Normal Entrance 13 F User Identification Mode Selection 14 G The Number of Identification Chances Setting up...

Страница 3: ...sensor Patent pending cutting edge technology Automatic vertical shutter Protection sensor for inserted finger LCD Battery condition display Main menu display Input condition display Die Casting keyp...

Страница 4: ...or mode setting FUNCTION KEY User registration procedure User deletion procedure BASIC MANUAL BATTERY COVER BDL 600 Built in Type C Base BDL 700 FRONT BASE Emergency Communication Terminal Connection...

Страница 5: ...idity Voltage Operating Environments 10 C 60 C 10 90 RH Option 5 0 8 0 V Power Adaptor Input Output AC 110V 220V 60Hz DC 12V 300mA Li ion Battery 7 2V 1850mA rechargeable Recognition Sensor Less than...

Страница 6: ...er Please refer to page 11 If the master user have registered before the master fingerprint will be required in first stage of user registration 2 Normal Access 1 Press power switch 2 Input USER ID 4...

Страница 7: ...its verification procedure If there is no key input for 5 seconds power will be off automatically ENT Enter Key After pressing a key press this key to input data to the BioDoremi DO 1 SI 7 Available...

Страница 8: ...rd user only Set present time to recode access history data Display previous recoded access data Download access data to PC Delete all recoded access data 7 HISTORY 1 MAST 2 USE 3 EMERGENCY 1 ALL 2 SE...

Страница 9: ...ed charge Waiting for input a fingerprint Put a Finger There is no user ID inputted Failed There is no fingerprint placed on the sensor Failed 1 Fingerprint verification failure Failed 2 Unregistered...

Страница 10: ...Press the No 1 MASTER REG to register Master User 1 MAST Master ID Input selected master ID 4 digit Press the ENT to register ID ENT Place master fingerprint on the sensor two times Register two imag...

Страница 11: ...print User 2 ID ENT User 2 Fingerprint SET Shutter Close Power Off User Sequence Registration User ID Input selected user ID 4 digit ENT Press the ENT key to register user ID User Fingerprint Place us...

Страница 12: ...aster has be registered Press the ENT key to advance for next procedure Master Fingerprint Place master fingerprint on the sensor Input USER ID to delete Press the ENT key to back main menu Press the...

Страница 13: ...me It was set as 5 seconds from factory User Fingerprint Place registered user fingerprint to the sensor If registered fingerprint is not verified well 1 clean sensor panel then try again 2 try again...

Страница 14: ...ered submenu of 1 N mode 1 ENT FP After push PWR button push ENT key before input fingerprint 2 PWR FP After push PWR button input fingerprint directly PWR SET 3 STA SET Shutter Close Power Off 1 1 1...

Страница 15: ...second SET Shutter Close Power Off 1 MOT 2 SOL Increase open time by 1 second 1 SUB 3 ADD ENT I Password User Registration User ID should be registered with fingerprint before registration of its pass...

Страница 16: ...git 01 12 Add Month 2 Digit 01 12 Subtract Date 2 Digit 01 31 Add Date 2 Digit 01 31 Subtract Hour 2 Digit 00 23 Subtract Hour 2 Digit 00 23 Add Minute 2 Digit 00 59 Subtract Minute 2 Digit 00 59 Add...

Страница 17: ...o use this function PWR Place Fingerprint Call to Setting Place Emergency Number LOCK OPEN PWR Emergency Number Input User ID Call to Setting Place LOCK OPEN O Battery Recharge Warning If external pow...

Страница 18: ...round the fingerprint sensor Testing lock relay open Testing emergency relay Testing keypad operation Testing all function 7 TEST 2 MOT 3 TCS 4 REY1 5 REY2 6 KEY 7 Auto Test 1 MOTs 1 S1 of 3 S2 on Tes...

Отзывы: