Fault Finding 

Symptom 

Possible Cause 

Remedy 

Pump will not 
‘Prime’ 
 

a.  Air getting into the suction 

hose/manifold 

b.  Worn piston seals 
c.  Ball checks not seating correctly 

a.  Check seals and hose connections 
b.  Replace piston seals 
c.  Inspect, clean/replace balls/seats 
 

Pump will not run

 

a.  No Air or Fluid supply 

 

b.  Air piston seal worn. 

 

c.  Pilot valve assemblies inoperable. 

 

d.  Main air valve inoperable 
 
e.  QE diaphragm defective 

 

f.  Ball checks not seating 

 

a.  Check air and fluid supply ball valves 

and supply hoses. 

b.  Replace Piston seal 
c.  Switch/interchange pilot valves to 

isolate faulty pilot valve and 
clean/replace. 

d.  Check clean/replace Air valve. 
e.  Check for constant exhaust air when 

pump is not running. Check/replace 
QE diaphragms  

f.  Inspect, clean and/or replace balls 

and seats. 

 

 

Pump runs but has 
excessive pulsation 

 

a. 

Air getting into fluid line, air supply 
restricted.

 

b. 

Obstructed fluid ball checks.

 

 

c. 

Worn air motor piston seals. 

 

d. 

Worn/failed air motor shaft seals. 

 

 
e. 

Worn fluid piston seal.

 

f. 

 Air exhaust restricted. 

 

 

a.  Check seals and hose connections. 

Check air supply 

b.  Remove, clean, and inspect seat, 

ball, and ball cage. Replace if 
suspect or worn. 

c.  Replace air motor piston seal. 
d.  Disassemble pump as required to 

replace air motor shaft seals. 

e.  Replace fluid piston seal. 
f. 

Check QE diaphragms and exhaust 
outlets.

 

 

Paint leaking into 
detection hose (38) 
Air bleeding from 
vent plug (36) 
 

a.  Bellows seal failure 
b.  Air motor shaft seal leaking. (Air 

leak from vent plug 36). 

 

a.  Replace bellows seal (27) 
b.  Check air motor shaft seal (6), 

replace as necessary 

 

Содержание Maple 7/15 10 40 41

Страница 1: ...Instruction Manual Maple 7 15 Pump Model 10 40 41...

Страница 2: ...Instruction Manual Page 2 of 16 Issue 1 5...

Страница 3: ...itary NPT Female Compressed Air Inlet 3 8 BSPP NPSM Air Volume cycle 0 33 SCFM 9 5 L m 45PSI 3 1 Bar 0 65 SCFM 18 5 L m 90 PSI 6 2 Bar Air Flow 15 cycles min 6 bar Air Flow 30 cycles min 6 bar 10 CFM...

Страница 4: ...Instruction Manual Page 4 of 16 Issue 1 5...

Страница 5: ...Instruction Manual Page 5 of 16 Issue 1 5...

Страница 6: ...Instruction Manual Page 6 of 16 Issue 1 5 KEY GREASE AGMD 010 LOCTITE TORQUE GREASE INTERNAL AGMD 010 MAINTENANCE ORDER REVERSE FOR ASSY MAGNET HAZARD ITEM 6 DETAIL...

Страница 7: ...19 165970 M4 PLAIN WASHER STST 4 20 165971 4 SPRING WASHER STST 4 21 171714 3 4 BALL 440C 2 22 177009 M12 X 35 CAPHEAD SCREW 8 23 192009 1 1 1 2 SANITARY CLAMP 2 24 192147 NAMEPLATE 1 25 192206 1 SAN...

Страница 8: ...8 Detail A ITEM PART No DESCRIPTION QTY REMARKS 50 162702 PISTON SEAL 1 51 165964 M12 x 40 GRUBSCREW ST ST 1 52 192759 PISTON SHAFT 2 53 192760 PISTON 1 GREASE AGMD 010 LOCTITE TORQUE GREASE INTERNAL...

Страница 9: ...PRING 1 61 162743 33 X 2 O RING PTFE 1 62 162744 23 52 X 1 78 ORING PTFE 1 63 162745 29 9 X 1 78 O RING PTFE 1 64 193181 0 875 BALL 1 65 193188 INLET SPRING KEEP 1 66 193189 PISTON SEAT 1 67 193358 46...

Страница 10: ...ET 2 83 0115 010018 VALVE BLOCK END CAP 2 84 0115 010020 DIAPHRAGM 2 85 0115 010021 O RING 1 5 X 36 2 86 0115 010049 O RING 2 x 20 2 87 0115 010073 M4 x 12 SHCS 8 88 0115 010097 VALVE BLOCK 1 89 0115...

Страница 11: ...Instruction Manual Page 11 of 16 Issue 1 5 Removal of a single fluid piston 16mm 10mm...

Страница 12: ...for constant exhaust air when pump is not running Check replace QE diaphragms f Inspect clean and or replace balls and seats Pump runs but has excessive pulsation a Air getting into fluid line air sup...

Страница 13: ...y Check for any general fluid or air leakage Weekly Inspect Pump for Correct operation Check for any excessive mechanical noise Check for excessive fluid pressure pulsation 6 Monthly Test Perform a pu...

Страница 14: ...ssembly or repair If an air lubricator is used then this must be maintained Set the pump speed to a slow cycle rate and start the pump to remove any air from the fluid circuit before increasing pressu...

Страница 15: ...Instruction Manual Page 15 of 16 Issue 1 5...

Страница 16: ...ral e mail info finishingbrands eu USA Canada Customer Service 195 Internationale Blvd Glendale Height IL 60139 630 237 5000 Toll Free Customer Service and Technical Support 800 992 4657 Toll Free Fac...

Отзывы: