TYPES OF INSTALLATION

2

5/16”

1/4”

Only 34 PSI at gun inlet

25 feet of 1/4” I.D. hose causes
a drop of 26 PSI between the
air supply and the gun.

(NOT RECOMMENDED)

48 PSI at gun inlet

25 feet of 5/16” I.D. hose
causes a drop of 12 PSI
between the air supply 
and the gun. For this reason
Binks recommends the use 
of 5/16” hose.

(RECOMMENDED)

With 60 psi applied at air supply

CONNECTING GUN TO
“PRESSURE ASSISTED”1 QT. CUP
(Figure 1)

The stainless steel pressure-assisted 1 quart
cup, 80-272, utilizes a low pressure air bleed
port on the gun head to slightly pressurize
the cup and provide fluid flow to the noz-
zle. A check valve prevents the cup from
depressurizing when the gun trigger is
released and airflow stops.

To connect the gun to the cup, remove
the plug (34) in the gun head and install
the hose barb fitting provided with cup
assembly. Attach cup assembly to 3/8"
NPS fluid inlet connection and firmly
tighten. The siphon tube should be angled
toward the front of the gun, i.e. under the
nozzles, and the pressure hose in the cup
lid positioned to the left of the trigger.
Connect check valve assembly hose from
barb fitting on gun head to check valve
inlet fitting on cup cover. Make sure the
check valve is connected so the air comes
from the gun, through the check valve,
into the cup.

Air pressure for atomization is regulated 
at the extractor. The flow of the fluid is
adjusted by the fluid valve control knob
on gun, viscosity of paint and air 
pressure.

PRESSURE CUP HOOKUP
(Figure 2)

For fine finishing with limited spraying.
Air pressure for atomization is regulated
at extractor; fluid pressure at cup regula-
tor. Pressure cup is also available less
regulator.

PRESSURE TANK HOOKUP
(Figure 3)

For medium production spraying (single
regulator). Air pressure for atomization is
regulated at extractor, fluid pressure at
tank regulator.

PRESSURE TANK WITH
2 REGULATORS (Figure 4)

The pressure to the tank is regulated by
the first regulator. The pressure for 
atomization is regulated by the second
regulator.

PRESSURE CIRCULATING
HOOKUP (Figure 5)

For heavy production spraying. Air pres-
sure atomization regulated at extractor.
Fluid pressure regulated at fluid regulator.

AIR PRESSURE

Atomizing pressure must be set prop-
erly to allow for the drop in air pres-
sure between the regulator and the
spray gun.

Binks oil and water extractor is important

.

Achieving a fine spray finish without the use of a good oil and water extractor is virtually
impossible.

A Binks regulator / extractor serves a double purpose. It eliminates blistering and spotting
by keeping air free of oil and water, and it gives precise air pressure control at the gun. 

Binks recommends using Model HFRL-508 Oil and Water Extractor / Regulator. See your
local distributor for other models.

Cross section view 

showing comparison of inside

hose diameters (actual size). 

60 lbs. regulated pressure

Air

Siphon Cup

Oil & Water
Extractor

Fluid Pressure Cup

FIG 3

Air

Fluid
Outlet

Air
Inlet

Oil & Water Extractor

Fluid

Pressure

Tank

FIG 4

FIG 5

Fluid
Regulator

Air Supply

Air Supply

Fluid

Pressure

Tank

Oil &
Water
Extractor

Air

FIG 1

FIG 2

Air

Cup Regulator

Oil & Water
Extractor

Fluid

Содержание MACH 1

Страница 1: ...e with the California South Coast Air Quality Management District regulations as a high volume low pressure airspray gun The air inlet passage in the gun body incorporates a venturi which limits airfl...

Страница 2: ...CUP HOOKUP Figure 2 For fine finishing with limited spraying Air pressure for atomization is regulated at extractor fluid pressure at cup regula tor Pressure cup is also available less regulator PRES...

Страница 3: ...ners in the cup and spray this through the gun until it is clean Blow air through gun to dry it When Used With Pressure Container Shut off air supply to container and release the pressure on the conta...

Страница 4: ...1 w Adj Fluid Inlet 37 54 4540 VITREOUS FLUID INLET ASSEMBLY 1 Optional 40 54 4541 VITREOUS FLUID INLET Optional 1 41 20 2227 5 O RING Buna Optional 1 42 54 4531 PACKING SPACER Optional 1 43 54 4542...

Страница 5: ...ions requiring more gradual fluid valve opening for metering control of fluid flow with trigger SIPHON FEED FINE FINISH Light to medium fluids Auto body spot repairs Medium to heavy fluids Auto body o...

Страница 6: ...5 NOZZLE ATOMIZING PSI NOZZLE AIRFLOW SCFM 6 STANDARD SIDE PORT CONTROL 3 4 5 6 0 9 5 6 0 8 5 10 7 6 8 11 0 14 9 7 5 13 5 18 10 8 0 15 0 19 HVLP AIR NOZZLE 90P 6 Standard Side Port Nozzle Nozzle Contr...

Страница 7: ...flow rate The fluid control knob 23 may be used to restrict the fluid nozzle 3 opening and reduce the fluid flow as necessary AIR NOZZLE FLUID NOZZLE NEEDLE ASSEMBLY 1 All nozzles and needles are pre...

Страница 8: ...2463R 9 Printed in USA 4 03 All Rights Reserved BINKS WORLDWIDE SALES AND SERVICE LISTING www binks com INDUSTRIAL FINISHING Binks has authorized distributors throughout the world FOR TECHNICAL ASSIST...

Отзывы: