EN
SPECIAL REQUIREMENTS FOR ATEX
1.
2.
3.
4.
5.
6.
7.
8.
WARNING
The flow gun must be earthed to dissipate any electrostatic charges which may be created by fluid
flows.
Electrical resistance from the flow gun to earth should be checked and a resistance of less than 10⁶
Ohms is required.
Ensure material supply is turned off and pressure is relieved from gun when not in use.
Set trigger lock to the locked position.
If the gun is to be left for a long period of time, it may be necesarry to flush through with solvent to
avoid a possible blockage of the fluid passageways.
Ensure a suitable nozzle is fitted to the gun.
Connect the gun to a suitable conductive hose. (If used in a hazardous area).
Ensure trigger lock is in the un-locked position.
Trigger the gun and slowly increase the pressure at fluid supply regulator, to ensure all air is
removed from hose and gun, until full flow of material is achieved.
Adjust supply pressure to determine optimal material flow rate.
Trigger off the gun.
NOTE
NOTE
The flow gun has been tested with demineralised water.
Please purge fluid passageways through with air before use.
START-UP & OPERATION SEQUENCE
This should be achieved with a conductive fluid hose.
77-3246 R1.2
8/20
www.carlisleft.com