BINKS EMS | OPERATION MANUAL
9.4
Dispense Pump Troubleshooting Checklist
The Dispense Pump has multiple components needed to verify proper operation. Go through this checklist to help identify
potential problems with the pump before disassembling. If the problem is still not corrected, it may be necessary to remove
the Dispense Pump and clean it thoroughly after flushing it with a solvent. No passageways should be clogged with material.
DISPENSE PUMP TROUBLESHOOTING CHECKLIST
Description
Pass/Fail
Check for air in all fluid lines. There must be no air bubbles anywhere
________
Verify there are no leaks anywhere on the pump fluid end.
________
Examine the Oil Reservoir. Look for overflowing or hints of hardener / catalyst
material in the reservoir.
________
Check that the system is not in an Alarm state. It is possible an Alarm is not
allowing the pump to run.
________
Visually inspect the ACME threaded rod. Look for damage and engagement with
the potentiometer gear.
________
Verify the flag indicator is tightly securing the ACME rod to the pump rod.
Inspect the Pump rod for hardened material that may prevent movement.
________
Change the Binks EMS to Standby mode and go to the PRIME screen. Trigger the
gun and Dispense Pump(F2). Ensure Poppet Valve operation. Confirm a constant
stream of material is exiting the gun.
________
Examine the stepper motor. Verify smooth operation when the pump is running.
There should not be any ‘stuttering’ movement of the pump. Unusual movement
could be attributed to a flow meter that needs cleaning.
________