23
BINKS EMS | OPERATION MANUAL
8.5
Prime Screen
This screen is used when priming hardener and resin into
the Binks EMS. It allows independent operation of the
various Resin color valves, and operates the Dispense Pump
for material loading. This mode requires the Binks EMS
to be in STANDBY mode but does not disable alarms.
Atomizing air must be off to load materials.
1. RESIN
By pressing F3 (RESIN) once, the Resin
Enable Valve will open, allowing pressurized fluid
to travel through the fluid lines. The gun must
be triggered with atomizing air off for successful
loading. Press F3 again to stop.
2. HARDENER
By pressing F2 (HARDENER) once,
the Dispense Pump valves will open, and the
Dispense Pump will cycle. The gun must be triggered
with atomizing air off for successful loading. Press
F2 again to stop.
3. Checkboxes
The indicating icon that shows
when either the hardener or resin is active.
4. Color Valve
The icon displaying which Resin
valve is being opened when the resin is enabled.
n
Color 0
is reserved for flushing solvent
n
Colors 1 through 6
are for paint resins
n
Color 7
is reserved for flushing air
1
2
3
4
!
WARNING
Always follow the PRIME mode with a color 0 (solvent) load
to flush out the fluid lines and prevent unmixed material
from being sprayed or hardening in the system.