background image

fluID nozzle optIons
material 

fluid nozzle no.

Very Light/Reduced Flow 

20T (.020" dia. opening)

light/medium: less than 15 to 20 seconds in a zAHN 2 Cup,
e.g., stains, varnishes, thin lacquers, automotive refinishing materials 

40T (.040" dia. opening)

medium: 20 to 30 seconds in a zAHN 2 Cup,  
e.g., general industrial coatings 

55T (.055" dia. opening)

Heavy: greater than 30 seconds in a zAHN 2 Cup,  
e.g., low VOCs coatings 

55T (.055" dia. opening)

  All fluid nozzles use the 2s air nozzle.

   The  2s air nozzle is recommended for siphon applications or pressure-assist applications.

For Binks Cub SL Spray Guns using pressure or pressure-assist, use nozzle 20T for light/medium 
materials and 40T for heavier materials. use of larger nozzles or of very light materials with a 
pressurized gun will result in excessive material flows and is not recommended.

aIr pressures anD flows
 

gun Inlet pressure 

nozzle atomizing 

nozzle atomizing 

 

(psI) 

air flow (scfm) 

pressure (psI) 

 20 

6.0 

3

 30 

7.5 

5

 45 

10.0 

9

 50 

11.0 

10

Gun inlet pressure is measured at the gun inlet fitting with the gun triggered.

aIr pressure recommenDatIons
type of material 

atomizing psI 

gun Inlet psI 

regulator psI 

Primer/Surfaces 

3-4 20-26 27-33

Light Stains/Inks 

4-5 

26-30 

33-38

Acrylic enamels 

6-7 

35-40 

44-47

Lacquers 

7-8 40-42 47-55

Low VOCs, urethanes 

8-10 

42-50 

55-59

Regulator pressures are based on 25' of 1/4" hose in good condition without quick disconnects or other 
restrictive fittings. Gun inlet pressures are measured at the gun air inlet with the gun triggered. use 
the Air Nozzle Test Gauge Accessory 54-4150 to confirm the atomizing/regulator pressure for your 
actual air supply set-up. These recommendations are typical for average fluids, and are intended to 
serve as a starting point. Adjust as necessary for your specific application. Regulator pressures for 5/16" 
hose are 3 to 5 PSI lower.

fluID nozzle optIons, aIr pressure recommenDatIons

7

Содержание Cub SL 7011 Series

Страница 1: ...ve touch up and detailing industries and is well suited to other specialty finishing and small area applications Several options in fluid nozzle sizes make the gun adaptable to a variety of uses See the Parts List on page 2 and Fluid Nozzle Table on page 7 for these options This Part Sheet contains an exploded drawing and detailed parts list to enable a complete understanding of the gun s construc...

Страница 2: ...3 54 4482 Trigger stud 1 24 54 4483 trigger screw 1 25 54 4462 trigger 1 26 54 4125 Spindle cap 1 27 54 4134 seal retainer 1 28 55 847 packing nut 1 29 55 846 Packing 1 30 54 4107 fluid inlet 1 4 NPS m 1 31 54 3928 Plug 10 32 x 1 4 Hex Head 1 32 54 3925 gasket 1 33 20 5740 O Ring 2 020 PTFE 1 34 54 4124 head insert 1 35 fluid nozzle 1 36 air nozzle 1 37 54 4123 RETAINING RING 1 Parts List When ord...

Страница 3: ...ube to connector on cup lid 2 Push the other end of vent tube down through loop on side of cup lip 3 Insert the threaded fluid inlet into the swivel nut taking care to position the vent tube away from the gun trigger 4 Rotate the swivel nut until tight to attach the cup to the fluid inlet how to set up your gun for pressure assist operations 1 Screw the swivel nut onto the threaded end of the flui...

Страница 4: ...ng your Siphon and Pressure Assist Cups 1 Remove the vent tube or check valve assembly from the gun and cup assembly 2 Unscrew the cup from the gun and rinse cup in solvent 3 Using a cloth soaked in solvent wipe the vent tube or check valve assembly to remove paint Cleaning gun used with pressure containers 1 Shut off air supply to container and release pressure on the container 2 Hold a piece of ...

Страница 5: ...taining ring 37 fluid inlet 30 air nozzle 36 fluid nozzle 35 head insert 34 o ring 33 from the front of gun 3 Unscrew the trigger screw 24 from the trigger stud 23 and remove the trigger stud and trigger from the handle assembly 2 Note the direction in which the spindle cap 26 is positioned 4 Use a screwdriver to unscrew the seal retainer 27 5 Push out the front u cup seal and replace it 6 Reassem...

Страница 6: ...nozzle left behind by improper cleaning Soak these parts in thinner to soften the material and remove it with brush or cloth Intermittent Spray Fluttering spray is caused by one of the following problems 1 The nut that attaches the fluid cup may be loose The packing nut 28 may be loose The packing 29 may be worn and need replacement The fluid nozzle 35 may be loose 2 Insufficient fluid available R...

Страница 7: ...ows Gun Inlet Pressure Nozzle Atomizing Nozzle Atomizing PSI Air Flow SCFM Pressure PSI 20 6 0 3 30 7 5 5 45 10 0 9 50 11 0 10 Gun inlet pressure is measured at the gun inlet fitting with the gun triggered Air Pressure recommendations Type of Material Atomizing PSI Gun Inlet PSI Regulator PSI Primer Surfaces 3 4 20 26 27 33 Light Stains Inks 4 5 26 30 33 38 Acrylic Enamels 6 7 35 40 44 47 Lacquers...

Страница 8: ...gun operating pressures We recommend that you use Nozzle Test Gauge Part No 54 4150 shown below for accurate nozzle operating pressures Test gauge ACCESSORY 54 4150 Gauge only 59 299 3 13 2013 Binks All rights reserved Printed in U S A U S A Canada Customer Service 195 Internationale Blvd Glendale Heights IL 60139 630 237 5000 Toll Free Customer Service and Technical Support 800 992 4657 Toll Free...