CS-11-02.1: Inline / Piggable Dual Modular Color Changer
GROUNDING OF THE COLOR CHANGERS
For safety, the color changer MUST be grounded. Using a 12-gauge wire, ground the output plate of the color changer to a true earth
ground. Using an ohm meter, check for ground, testing the earth ground to the purge assembly top plate. The resistance should be 10
ohms or less.
OPERATION (Continued)
FLUID INLET AND OUTLET FITTINGS
The in and out of the pipe assemblies have standard sanitary fittings.
The color changer MUST be properly grounded. Proper grounding (as described below) will prevent static
charge build-up and possible discharge from the color changer.
WARNING
NOTE - IN and OUT hoses CAN be reversed on the color changer.
AIR PILOT HOSE
Each color changer valve requires a 5/32”(4mm) pilot hose to activate the color valve.
FLUID OUTPUT HOSE
The fluid output hose of the color changer has a 3/8”NPS (M) fitting. For safety and solvent savings, it is recommended that a Teflon
hose be used between the color changer and the spray device.
OHMS
10
0
GROUND WIRE