CS-11-02.1: Inline / Piggable Dual Modular Color Changer
This information is intended ONLY to indicate the general installation parameters of this product and, where applicable,
its working relationship to other Ransburg system components in typical use.
Each installation is unique and should be directed by an authorized Ransburg representative or conducted using the
Ransburg installation drawings provided for your particular installation.
COLOR CHANGER INSTALLATION PROCEDURES
Determine Location for Color Changer
The color changer should be located as close as possible to the spray device in order to save paint and solvent. If possible, use an
enclosure to protect the color changer from airborne paints and solvents.
Calculate Footprint of Color Changer (See Mounting Single Valve Color Changer Figure)
To calculate the footprint of the color changer add:
1. The dimension of the purge assembly (if used).
2. The dimension(s) of the color block(s) used to create the desired number of color valves.
3. The dimension of the inlet/outlet block.
Dimension of Purge Assembly:
2.60” (66.04mm)
Dimension of Color Block Assembly:
2.064” (52.43mm)
Dimension of Spacer Block:
.936” (23.77mm)
Dimension of Inlet or Outlet Block:
.655”(16.64mm)
Example of 1/2” and 3/4” Pipe Assembly with 2 Color Blocks:
Inlet Block
.655”
.655”+ .655”+ 2.064”+ 2.064” = 5.438”(138.13mm)
Outlet Block
.655”
#1 Color Block
2.064”
#2 Color Block
2.064”
Section 3: INSTALLATION
3.13
[79.50]
2.064
[66.04]
2.064
[66.04]
.655 [16.64]
EXAMPLE OF A 2 COLOR UNIT WITH PURGE BLOCK ATTACHED FOR A
COMBINATION INCLUDING 1/2" AND 3/4" PIPE SIZE (NO SPACER REQUIRED)
2.064
[52.43]